3-40
Memory switch 07x : Operation
Memory switch 076 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
Timing to turn off the S-
Relay at fax reception.
Adjust this setting when a private exchanger disconnects the
line when S-Relay is turned off.
Bit
7654
time
1111
1500 seconds
1110
1400 seconds
:
:
1010
1000 seconds
1001
900 seconds
0100
800 seconds
:
:
0100
500 seconds
0100
400 seconds
0011
300 seconds
0010
200 seconds
0001
100 seconds
0000
10 seconds (default)
6
0
5
0
4
0
3
1
Display when there is no
TTI
0 : No
1 : Yes
2
0
Factory use only
—
1
1
Factory use only
—
0
0
Factory use only
—
Memory switch 077 ~ 079 : Factory use only
Memory switch 08x : Not used