3-34
Memory switch 06x : Remote reception
Memory switch 060 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
Factory use only
—
6
1
CML relay off time after di-
aling
0 : 1 sec.
1 : 200 msec.
When dialing from the keypad, phone line noise may occur as
the CML relay switches on and off.
Set this switch to “0” to avoid this.
5
0
DTMF tones heard through
handset
0 : No
1 : Yes
Determines if DTMF tones are produced through the handset
in off-hook dialing.
4
1
Factory use only
—
3
0
Factory use only
—
2
0
Factory use only
—
1
0
Factory use only
—
0
0
Factory use only
—
Memory switch 061 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
Factory use only
—
6
0
Factory use only
—
5
1
Factory use only
—
4
1
Factory use only
—
3
0
Off-hook / on-hook detect
time
Sets the time interval between the on-hook and off-hook (or
off-hook/on-hook) condition.
Switch 3210 Time
0000 0 ms
0001 100 ms
0010 200 ms
0011 300 ms
0100 400 ms
Initial setting
0101 500 ms
0110 600 ms
0111 700 ms
1000 800 ms
1001 900 ms
1010 1000 ms
1011 1100 ms
1100 1200 ms
1101 1300 ms
1110 1400 ms
1111 1500 ms
2
1
1
0
0
0
Содержание bizhub 25e
Страница 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Страница 2: ......
Страница 6: ...iv ...
Страница 48: ...1 42 ...
Страница 76: ...2 28 ...
Страница 153: ...3 77 First page of the report The resettable counter cleared date is printed with six figure of date month year ...
Страница 154: ...3 78 Second page of the report ...
Страница 155: ...3 79 Third page of the report ...
Страница 156: ...3 80 Fourth page of the report ...
Страница 200: ...3 124 ...
Страница 201: ...3 125 ...
Страница 254: ...5 4 5 2 1 URADF TRAY DOCUMENT 1 Pull and remove the TRAY DOCUMENT 2 from the Guide outer B up 1 ...
Страница 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Страница 353: ......