3-36
Memory switch 06x : Remote reception
Memory switch 064 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
CNG detect period after
TAD begins recording ICM
Sets the period during which CNG is detected after the TAD
begins recording incoming message.
Switch 7654 Time
0000 0 sec
0001 10 sec
0010 20 sec
0011 30 sec
Initial setting
0100 40 sec
0101 50 sec
0110 60 sec
0111 70 sec
1000 80 sec
1001 90 sec
1010 100 sec
1011 110 sec
1100 120 sec
1101 130 sec
1110 140 sec
1111 150 sec
6
0
5
1
4
1
3
0
CNG detect period after
TAD answers
Sets the period during which CNG is detected after the TAD
answers an incoming call.
Switch 3210 Time
0000 0 sec
0001 10 sec
Initial setting
0010 20 sec
0011 30 sec
0100 40 sec
0101 50 sec
0110 60 sec
0111 70 sec
1000 80 sec
1001 90 sec
1010 100 sec
1011 110 sec
1100 120 sec
1101 130 sec
1110 140 sec
1111 150 sec
2
0
1
0
0
1
Incoming rings
CNG detection is active
CNG detection is active
TAD plays Outgoing message
TAD records Incoming message
(Adjusted by Memory switch 64, bit 0-3)
(Adjusted by Memory switch 64, bit 4-7)
Содержание bizhub 25e
Страница 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Страница 2: ......
Страница 6: ...iv ...
Страница 48: ...1 42 ...
Страница 76: ...2 28 ...
Страница 153: ...3 77 First page of the report The resettable counter cleared date is printed with six figure of date month year ...
Страница 154: ...3 78 Second page of the report ...
Страница 155: ...3 79 Third page of the report ...
Страница 156: ...3 80 Fourth page of the report ...
Страница 200: ...3 124 ...
Страница 201: ...3 125 ...
Страница 254: ...5 4 5 2 1 URADF TRAY DOCUMENT 1 Pull and remove the TRAY DOCUMENT 2 from the Guide outer B up 1 ...
Страница 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Страница 353: ......