3-69
Unique Switch 09x : Miscellaneous
Unique Switch 096 :
Switch
Initial
Setting
Adjust
Usage/Comments
7
1
Warn that fuser switches are
in envelope-printing position
0: No
1: Yes
When this switch is “Yes” (1), the machine displays
a warning message that the fuser switches are in
envelope-printing position when copying or printing
envelopes is finished.
6
0
Factory use only
5
0
How long to display the
warning of envelope-printing
position
Switch 6 5 4 (minutes)
1 1 1
240
1 1 0
120
1 0 1
60
1 0 0
30
0 1 1
20
0 1 0
10
0 0 1
5
0 0 0
no limit
4
0
3
0
2
0
Factory use only
1
1
Displays warning at fuser life
0: Yes
1: No
When this switch is “Yes” (0), the machine displays
a warning message that the fuser has come to its
quality life.
0
0
Factory use only
Unique Switch 097
—
Factory use only
Unique Switch 098 :
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Respond warm-up condition
as ready on SNMP
0 : Respond as warm-up
1 : Respond as ready
To print on Row port correctly by AS400, set this
switch to “1”.
When this switch is “1”, SNMP manager such as
WebJetAdmin displays “Ready” even if the printer
is in warm-up condition. When the printer warms up
while it is receiving information on Row port, the job
will be divided. The latter divided job will be printed
with initial font as it has no font information. This
setting will avoid this font issue.
5
0
Respond Sleep condition as
ready on SNMP
0 : Respond as sleep
1 : Respond as ready
To print on Row port correctly by AS400, set this
switch to “1”.
When this switch is “1”, SNMP manager such as
WebJetAdmin displays “Ready” even if the printer
is in sleep condition. When the printer sleeps while
it is receiving information on Row port, printing will
be disabled. To enable printing again, this error
should be recovered with administrator authority,
and this setting will avoid this issue.
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
Factory use only
0
0
Factory use only
Unique Switch 099
—
Factory use only
Содержание bizhub 25e
Страница 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Страница 2: ......
Страница 6: ...iv ...
Страница 48: ...1 42 ...
Страница 76: ...2 28 ...
Страница 153: ...3 77 First page of the report The resettable counter cleared date is printed with six figure of date month year ...
Страница 154: ...3 78 Second page of the report ...
Страница 155: ...3 79 Third page of the report ...
Страница 156: ...3 80 Fourth page of the report ...
Страница 200: ...3 124 ...
Страница 201: ...3 125 ...
Страница 254: ...5 4 5 2 1 URADF TRAY DOCUMENT 1 Pull and remove the TRAY DOCUMENT 2 from the Guide outer B up 1 ...
Страница 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Страница 353: ......