Komptec GmbH. KT-90A User Manual
Page 35 of 52
v1.0a; 8 May 2016
Every 10 Hours for Breathing Air, 40
hours for Industrial
Chapter Date
Signature
Change filter
9.3.2
Check O-rings on the filter
- -
Every 500 Operating Hours
Chapter Date
Signature
Oil change
9.3.3
Change O-rings on the filter
- -
Change O-rings on the cylinder cover
- -
Clean the filter unit
- -
Check safety valve
- -
check exhaust
- -
Check all operation and leaks
- -
Change intake filter
- -
Replace piston rings
- -
Check tightness of all cooler and connecting
lines
- -
Every 1000 Operating Hours
Chapter Date
Signature
Replace belts
- -
At least once per year
Chapter Date
Signature
Oil Change
9.3.3
Change O-rings on the filter
- -
Change the filter
Clean the filter unit
Check the safety valve
Check exhaust
Check all operation and check for leaks
Содержание KT-90A
Страница 4: ...Komptec GmbH KT 90A User Manual Page 4 of 52 v1 0a 8 May 2016...
Страница 43: ...Komptec GmbH KT 90A User Manual Page 43 of 52 v1 0a 8 May 2016 Figure 3 First Stage 2016 KompTec GmbH...
Страница 44: ...Komptec GmbH KT 90A User Manual Page 44 of 52 v1 0a 8 May 2016 86 87 Figure 4 Second Stage 2016 KompTec GmbH...
Страница 45: ...Komptec GmbH KT 90A User Manual Page 45 of 52 v1 0a 8 May 2016 Figure 5 Third Stage 2016 KompTec GmbH...
Страница 47: ...Komptec GmbH KT 90A User Manual Page 47 of 52 v1 0a 8 May 2016 Figure 7 Filter Housing 2016 KompTec GmbH...