Komptec GmbH. KT-90A User Manual
Page 31 of 52
v1.0a; 8 May 2016
8.2.1.6.
Complete the Filling process
1.
Close the filling valve
2.
Slowly open the Conden-
sate Drain and drain the
condensate
3.
Bleed pressure in hose
then remove cylinder
8.3.
Extended Storage
If the compressor will not be used for an extended period:
•
Run the compressor for a few minutes with the fill valve open to flush
out the residual condensate. Stop the compressor, disassemble the in-
take filter, and add a few drops of oil so that a light film of lubricant
is aspirated and penetrates the interior of the compressor. Stop the
compressor and refit the intake filter.
•
Clean the external parts, eliminate any moisture, salt or oil deposits.
•
Store the compressor in a clean, dry location.
8.3.1.
Waste Disposal
Use of the compressor generates waste that is classified as special. Wastes
not classified as urban waste must be treated as special waste. Deteriorated
or obsolete machines are also classified as special waste.
Waste oil must be disposed of in compliance with local ordinances.
Содержание KT-90A
Страница 4: ...Komptec GmbH KT 90A User Manual Page 4 of 52 v1 0a 8 May 2016...
Страница 43: ...Komptec GmbH KT 90A User Manual Page 43 of 52 v1 0a 8 May 2016 Figure 3 First Stage 2016 KompTec GmbH...
Страница 44: ...Komptec GmbH KT 90A User Manual Page 44 of 52 v1 0a 8 May 2016 86 87 Figure 4 Second Stage 2016 KompTec GmbH...
Страница 45: ...Komptec GmbH KT 90A User Manual Page 45 of 52 v1 0a 8 May 2016 Figure 5 Third Stage 2016 KompTec GmbH...
Страница 47: ...Komptec GmbH KT 90A User Manual Page 47 of 52 v1 0a 8 May 2016 Figure 7 Filter Housing 2016 KompTec GmbH...