3.
General safety
3.1.
Obligation of diligence
To ensure maximum working efficiency, Komptec has constructed the compressor with
carefully selected components and materials. The compressor is tested prior to delivery.
Continued compressor efficiency over time will also depend on proper use and mainte-
nance as per the instructions contained in this manual.
However, this safety can only be achieved in operational practice if all necessary
measures are taken. It is the obligation of the operator to follow these instructions and to
monitor their implementation.
The operator must in particular ensure that
−
the compressor is only used as intended (see chapter description)
−
the compressor is operated only in good working condition and safety equipment in
particular is checked regularly for proper functioning,
−
required personal protective equipment for the operating, maintenance and repair
personnel are available and are in use,
−
the user manual is always in a legible condition, is complete and is available at the
site of the compressor,
−
only sufficiently qualified and authorized personnel operate the compressor and per-
form maintenance and repairs,
−
the personnel are regularly instructed in all applicable questions regarding occupa-
tional safety and environmental protection and knows the operating instructions and
particularly the safety instructions contained therein,
−
safety instructions and warnings are all mounted on the compressor are not removed
and remain legible.
3.2.
Basic safety measures
3.2.1.
Principle; Intended Use
The compressor has been built according to the prior art and the recognized safety regu-
lations. Nevertheless, danger to life and limb to the user and to third parties, or damage
to the compressor or other tangible assets can arise. The following table shows how this
manual is organized and when and what the individual sections are needed.
The compressor must be maintained in good working condition. In particular, faults that
can impair safety must be rectified immediately!
The compressor is intended exclusively for filling compressed air cylinders. Any other
use or extended use is considered improper. The manufacturer is not liable for any result-
ing damage. The risk is borne solely by the user.
Intended use also includes complying with the operating instructions and compliance with
the inspection and maintenance conditions.
3.2.2.
Responsibility
The operating instructions must remain accessible and kept at hand at the compressor!
Содержание KT-90A
Страница 4: ...Komptec GmbH KT 90A User Manual Page 4 of 52 v1 0a 8 May 2016...
Страница 43: ...Komptec GmbH KT 90A User Manual Page 43 of 52 v1 0a 8 May 2016 Figure 3 First Stage 2016 KompTec GmbH...