AKD-C Installation | 7 Technical description and data
7.2 Mechanical Data
Mechanical data
Units
AKD-C01007-x
Weight
kg
3.8
Height front
mm
290
Height back
mm
329
Width
mm
80
Depth, without connectors
mm
198
Depth, with connectors
mm
231
7.3 Electrical Data
Electrical data
Units
Value
Rated supply voltage (L1, L2, L3)
V~
3 x 400 V to 3 x 480 V, ±10%
Rated supply input frequency
Hz
40 Hz to 70 Hz
Rated input power
at 3x400 V
kVA
9.2
at 3x480 V
kVA
11
Rated input current at 3x400/480 V
A
14
Permitted switch on/off frequency, mains
1/h
30
Max. inrush current
A
5
Rated DC bus link voltage
(Bus Turn on Delay 3ph 1 sec)
V=
565 to 680
Standby DC power voltage
V=
55 ±10%
Continuous total output current
A=
17
Peak total output current (for 1 s, ± 3%)
A=
34
Continuous output power
at 3x400 V
kVA
9.2
at 3x480 V
kVA
11
Peak output power (for 1 s)
at 3x400 V
kVA
18.4
at 3x480 V
kVA
22
Technical data for regen circuit
—
Thermal dissipation at 24V standby
No AKD-N (min)
W
8.6
16 AKD-N (max)
W
40
Thermal dissipation at rated current (without
regen power)
W
125
Noise emission (low speed / high speed fan)
dB(A)
40 / 60
Aux. voltage supply (PELV)
V=
24 V (±10%, check voltage
drop)
Aux. voltage supply current
maximum required
A=
14
per AKD-N without brake
A=
0.33
Aux. voltage inrush current
A=
16
Protection class
-
IP20
30