9.10.3 Digital Output (X15)
The drive supplies one digital output (X15/1 to X15/2, (
# 73). Choose the required function
in the setup software. Messages from pre-programmed functions stored in the AKD-C can be
output here. A list of these pre-programmed functions can be found in the setup software. If
the output is to be assigned to a pre-programmed function, then the parameter set must be
saved in the AKD-C.
Technical characteristics:
As per IEC61131-2 type 1
Floating, max. 30 VDC, 100 mA
Short circuit proof
Galvanic isolation for 250 VDC
Can be wired as active low or active high (see examples below)
Update rate: 250 µs
Wiring diagram:
AKD-C Installation | 9 Electrical Installation
Kollmorgen | kdn.kollmorgen.com | February 2018
75