44
•
Front Panel Interface
XX102-00-00 Rev 203 KOL-RAID3 RAID Storage Systemd
HD Write Cache
The Write Cache records data at the same time as the hard disk. If the same data is needed right away, it is sent from the
cache, rather than reading is from the disk, speeding up read performance.
HD Write Cache Enabled
What you can do:
Press
SEL
:
Toggles the
HD Write Cache
between
Enabled
or
Disabled
Press
:
Does nothing.
Press
:
Does nothing.
Press
EXIT
:
Returns to the
Advance Feature
menu.
Rebuild Media Error
Rebuild Media Error refers to whether the Controller will rebuild an array when it encounters a media error (a bad sector)
on one of the disk drives. This event will cause the array to go “offline”.
When
Abort
is selected, the Controller will stop a rebuild operation if it encounters a bad sector. You must replace the
disk drive with the bad sector to restore array function.
When
Skip
is selected, the Controller will continue rebuilding and work around the bad sector and restore array function
with the existing disk drive.
Rebuild Media Err Abort
What you can do:
Press
SEL
:
Toggles the
Rebuild Media Err
between
Abort
or
Skip
Press
:
Does nothing.
Press
:
Does nothing.
Press
EXIT
:
Returns to the
Advance Feature
menu.
Always On
Configure Cache
Write Back
Write Thru
Write Cache
2 default
5
10
30
60
Cache Flush Frequency
Read Ahead