Installation
XX102-00-00 Rev 203 KOL-RAID3 RAID Storage Systemd
SCSI-IN
SCSI-OUT/TERM
Figure 6.
SCSI Terminator attaches to the SCSI Output Connector.
Caution
Improper system operation may occur if the SCSI termination is
incorrect. Proper termination and SCSI-3 compliant cables must be
used. A SCSI-3 compliant cable is included with the unit.
Daisy Chaining Multiple Arrays
Use a standard 68-pin SCSI-3 cable assembly to attach the array to the SCSI chain. Attach each cable to the individual
units to be connected on the SCSI bus. Ensure that each device has a unique SCSI ID and that only the first and last
devices are terminated.
If the last unit in the chain has internal SCSI termination (no external terminator was included), it will terminate itself
automatically.
If the last unit in the chain does not have internal SCSI termination (an external terminator was included), attach the
external terminator to the SCSI Output Connector as shown in Figure 7.
Figure 7.
Daisy Chaining Several Units Together
Terminator
SCSI Output
Connector