IK-12 NEXT
- 24 -
<About error numbers> Error indications are three-
digit numbers that start with “E.”. Example indication
Error
number
Error details
Cause
Corrective action
001
Link unit configuration failure
error
There may be a contact failure
in the wiring between electrical
boards (connector numbers
CN2, 3 for all boards in
common, connector numbers
CN4, 5 for the L-DSP display
board).
Check for cable disconnections, and for
contact failures of connectors and crimp-type
terminals.
(The LEDs on each board will flash when the
power is turned on: if the LEDs do not flash or
light, the circuit board may be faulty.)
002
Power failure detection error
This is an error that occurs on
other equipment.
In the event that it is displayed, contact the
distributor where you purchased this product
or our sales office.
003
Inverter error
004
Emergency stop error
005
3-phase power supply error
006
Breaker OFF error
007
Encoder line connection error
The encoder line may be
connected to MD-CN10 on the
L-MD-A board.
Connect the encoder line to MD-CN5.
008
Motor deviation error
There may be a contact failure
on the motor line or the encoder
line.
Check for disconnections in all wires, and for
contact failures of connectors and crimp-type
terminals. Connect the motor line to MD-CN4,
and the encoder line to MD-CN5, on the
L-MD-A board.
010
Welding current detection
signal ON timeout (5 seconds)
error
This is an error that occurs on
other equipment.
In the event that it is displayed, contact the
distributor where you purchased this product
or our sales office.
011
Signal logic inversion error
while detecting welding
current
012
Encoder selection error
013
Unit configuration unsuitable
error
014
Weld movement distance
during tack operation error
016
Servo driver error
This is an error that occurs on
other equipment.
In the event that it is displayed, contact the
distributor where you purchased this product
or our sales office.
017
Copying signal error
018
Thermal guard error
019
Thermal guard error
020
Link unit configuration failure
error
021
X-axis-direction derailing error
022
Y-axis-direction derailing error
023
Z-axis-direction derailing error
024
Motor overload error
(encoder equipped)
An abnormal load may be being
applied to the drive section or
motor.
Remove any abnormal load from the drive
section or motor.
025
Carriage backup error
(Parameter)
It is possible that the power was
turned off during carriage
operation or fine adjustment
movement by limit switch, and
the backup was not
implemented correctly.
Turn the power off and back on again.
If the error display indication is not cleared
after repeating the above several times,
replace all the circuit boards being used.
026
Carriage backup error
(System Parameters)
125
WU-3R backup error
(parameter)
This is an error that occurs on
other equipment.
In the event that it is displayed, contact the
distributor where you purchased this product
or our sales office.
126
WU-3R backup error
(
System Parameters)
※
To recover from an error, unplug the power cable from the operation panel, turn off the power supply, check the corrective
action described above, plug the power cable back into the operation panel and turn the power back on.
※
When an error occurs, the error indication is reset by pressing the CREEP button, but eliminate the cause by referring to the
corrective action described above before pressing the button.
Содержание IK-12 NEXT
Страница 50: ...IK 12 NEXT 46 10 Wiring diagram...
Страница 51: ...IK 12 NEXT 47 11 Assembly drawing of IK 12 NEXT 215mm 8 465inch 220mm 8 661inch 432mm 17 008inch...
Страница 52: ...IK 12 NEXT 48 012 Parts list 12 1 Main body and inside parts...
Страница 54: ...IK 12 NEXT 50 12 2 Outside parts...
Страница 56: ...IK 12 NEXT 52 12 3 Electrical parts 103...