25
1367864-W2-C
Symptoms
Probable Cause
Possible Remedy
Noise
The product will make a mechanical
noise during (and just after) normal
operation
Digital Mixing valve air locking
Check for correct installation
practices, repeat commissioning
procedure
and
rearrange
pipework to avoid airlock forming.
Water Hammer
Ensure all pipework is securely
fixed.
Amplified acoustic noise from the
Digital Mixing valve mechanism
due to structure of the mounting
The type of wall or surface the
appliance is fixed to will affect the
perceived noise level; solid walls
will provide a quieter operation.
Digital Mixing valve failure
Contact Rada.
False triggering
Protective film not removed from
product
Remove protective film.
Dirty sensor window
Clean sensor window.
Reflective surfaces
Infra Red sensors activated
by reflective surfaces such as
polished basins, Hi-Vis jackets
and mirrors.
Ambient light conditions
Direct sunlight or constant
shadowing of the sensors to be
reduced.
Digital Mixing valve failure
Contact Rada.
Water leaking from product Damaged seal
Replace seal and re-fit product.
Product not fully engaged to
manifold
Correctly engage product to
manifold.
Содержание rada Intelligent Care MX1 60