27
1367864-W2-C
Error Codes
Probable Cause
Possible Remedy
Temp imbalance
Unstable supply
Non Product Fault - The supply
conditions are out of specification
Valve will self clear fault.
Hot inlet water supply temperature
is too hot or fluctuating
Reduce
hot
inlet
water
temperature to between 55°C and
65°C, refer to
“Specifications”.
Inlet water supply pressures are
unstable or imbalanced
Ensure the water supply
pressures are stable and
nominally equal, refer to
“Specifications”.
Motor homing error
Recovered EE error
EE error - reverted to
default
Non Product Fault
Re-set the product by turning
electrical supply off for 30
seconds then re-apply power.
Open circuit error
Software failure
Re-set the product by turning
electrical supply off for 30
seconds then re-apply power.
Loose internal wiring connections
(Thermistor)
Ensure all wiring connections
are securely made.
Thermistor failure
Contact Rada.
Unconfigured
A to D Read Error
RAM error
EE Error
External EE error
RTC Fault
Flash Error
Scheduler Error
IR not calibrated
Software failure
Re-set the product by turning
electrical supply off for 30
seconds then re-apply power.
PCB failure
Contact Rada.
Shut Off Mechanism
Controller Error
Software failure
Re-set the product by turning
electrical supply off for 30
seconds then re-apply power.
Loose internal wiring connections
(Solenoid and PCB)
Ensure all wiring connections are
securely made.
Digital Mixing valve failure
Contact Rada.