23
1367864-W2-C
Symptoms
Probable Cause
Possible Remedy
Keeps cutting out
Product has entered an error mode
indicated by a flashing
“spanner”
symbol
Refer to Error Code Log
Inlet water supply isolators not fully
turned on
Check and remedy.
Inlet filters or check valves blocked Check and remedy.
Outlet spout, hose or handset
blocked
Check and remedy.
Reversed inlet supplies
Check and remedy.
”Run time”
is set too short.
Commission the run time using
the
“RADA AP1”
.
“Blocking”
time set
Commission
“Blocking”
time
using the
“RADA AP1”
.
Digital Mixer valve air locking
Check for correct installation
practices, repeat commissioning
procedure
and
rearrange
pipework to avoid airlock forming.
Digital Mixing valve failure
Contact Rada.
Inlet pressures and/or temperatures
are unstable or spiking
Check and remedy, refer to
“Specifications”.
Outlet temperature too
cool
Temperature adjustment set too
low
Increase temperature control -
Some models only.
Blend temperature set too low
Re-commission blend
temperature using the
“RADA
AP1”
.
Inlet filters or check valves blocked Check and remedy.
Outlet spout, hose or handset
blocked
Check and remedy.
Reversed inlet supplies
Check and remedy.
Hot inlet water supply temperature
is too cool
Increase hot inlet water
temperature to between
55 °C and 65 °C, refer to
“Specifications”.
Insufficient quantity of stored hot
water
Hot water supply running out,
increase storage capacity.
Содержание rada Intelligent Care MX1 60