Factory Default Settings
RADA App Tile / Section
Adjustable
Temperature
Varient
Fixed
Temperature
Varient
Range
Units
Min Value
Max Value
1. Valve Setup / 4. Installation Setup
1. Setup Advice
Info Field
2. Valve Identity
Editable Text Field
3. Outlet Type and Sub Type
Info Field
4. Unit Address
17
17
1
31
5. Valve Date and Time
24 Hr Clock
DD/MM/YYYY
6. Last Service and Time
Info Field
7. Flow Calibration
8. Minimum Flow Limit
5
5
1
100
9. Maximum Flow Limit
13
13
1
100
10. Valve DOB
Info Field
11. Calibration
N/A Set to max 300, 300
12. IR Calibration
Factory Programmed - typical Range 180 - 220
13. Pin
0001 - 9999 Permisable. Re-entry of 5945 Not Permitted
14. Tap Interface
Info Field
15. Operational State
Enable
Enable
Enable, Disable
16. Tasks
Apply Changes to Valve / Undo Changes
1. Valve Setup / 5. Outlet Setup
1. Type
Info Field
2. Sub Type
On/Off
On/Off
(On/Off), Timed
Blocking
N/A
3. Outlet Selection
Info Field
4. Full Cold Mode
Disabled
Disabled
Start Cold
Enabled
Disabled
Start Cold
Enabled
Disabled
5. Minimum Temperature
37
N/A
33
45
0.5 deg C
6. Default Temperature
39
38
33
45
7. Maximum Temperature
41
N/A
33
45
0.5 deg C
8. Flow Rate Setup
N/A
9. Default Flow Rate
50
50
10
100
%
10. Outlet Timeout
5 Min
5 Min
0s
30 Min
Seconds / min
11. Run on Time
5 S
5 S
1
60
Seconds
12. Temperature Memory
40 S
N/A
0
5 Min
Seconds / min
13. Blocking Time
1
1
1
25 Min
Seconds / min
14. Temperature Scale
9 Increments
N/A
9, 5 Increments)
15. Tasks
Apply Changes to Valve / Undo Changes
1. Valve Setup / 6. Duty Flush Setup
1. Activation
Manual
Manual
Manual, Automatic