Symptoms
Probable Cause
Possible Remedy
Flow rate too low
Inlet water supply isolators not fully
turned on
Check and remedy.
Inlet filters or check valves blocked Check and remedy.
Outlet spout, hose or handset
blocked
Check and remedy.
Reversed inlet supplies
Check and remedy.
Inlet Water pressures too low
Check specification.
Digital Mixer valve air locking
Check for correct installation
practices, repeat commissioning
procedure
and
rearrange
pipework to avoid airlock forming.
Digital Mixing valve failure
Contact Rada.
Flow rate too high
Inlet water pressures too high
Check specification.
Inlet check valves / flow regulators
not fitted
Check and remedy.
Digital Mixing valve failure
Contact Rada.
Outlet flow rate fluctuates
Inlet filters or check valves blocked Check and remedy.
Outlet spout, hose or handset
blocked
Check and remedy.
Reversed inlet supplies
Check and remedy.
Inlet water supply pressures are
unstable or imbalanced
Ensure the water supply
pressures are stable and
nominally equal, refer to
“Specifications”
.
Digital Mixing valve air locking
Check for correct installation
practices, repeat commissioning
procedure
and
rearrange
pipework to avoid airlock forming
Digital Mixing valve failure
Contact Rada.