Electrical
PSU
Valve
Supply Voltage
100 - 240 V 50/60 Hz
12 V DC
Rated Input Current
1 A
2.0 A
Water Ingress Protection
IP X4
IP X4
Protection Against Electric Shock
Class II (double insulated)
Class III (SELV)
Pollution Degree
2
2
Rated Impulse Voltage
2.5 kV
18 V
Performance
Factory pre-set temperature
39°C
Factory pre-set temperature range
37°C - 41°C
Programmable temperature range
33°C - 45°C (Full cold can be selected during
programming)
General
PSU
Valve
Maximum Ambient Temperature
50°C
40°C
Minimum Ambient Temperature
1°C
1°C
Maximum Humidity
95% rH
95% rH
Water Supply
Water connections
15 mm Compression or 1/2” BSP
Minimum dynamic pressure
100 kPa (1.0 bar)
Maximum dynamic pressure
500 kPa (5.0 bar)
Maximum static pressure
1000 kPa (10.0 bar)
Supply pressure differential
Equal pressure recommended - inlet pressures
must be stable for optimum performance.
Minimum recommended differential
between hot supply and outlet temp
(consistent with HSE Guidelines)
7°C
Hot supply temp
55°C - 65°C (60°C - 65°C Recommended)
Cold supply temp
1°C - 25°C
Maximum disinfection temperature
80°C
Duty Cycle
80% @ 40°C
For Type 3 installations, the supply conditions specified in the TMV3 Requirements manual take
precedence over the operating parameters which follow.