9
1493953-W2-A
Installation Requirements
Plumbing
1. The plumbing installation must comply with all national or local water regulations
and all relevant building regulations, or any particular regulation or practice
specified by the local water supply company.
2.
DO NOT
use sealing compounds on any pipe fitting or joints.
3.
DO NOT
install the product in a position in which service access is limited.
4. Decide on a suitable position for the shower (minimum distance of 200 mm from
the ceiling to allow for cover fit and removal).
5. The position of the shower and shower fittings must provide a minimum gap of
25 mm between the showerhead and the spill over level of any bath, shower
tray or basin and a minimum gap of 30 mm between the showerhead and the
spill over level of any toilet, bidet or other appliance with a Fluid Category 5
backflow risk (see diagram on page 11).
6. The shower is suitable for installation within the shower area and is fitted with
a pressure relief valve. It must be positioned over a water catchment area with
the controls at a convenient height for the user.
7.
The shower must be fitted to a waterproof flat and even wall surface.
8.
DO NOT
fit the shower to the wall and tile up to the case.
9.
DO NOT
seal the gap between the shower and the wall surface.
10. The showerhead should be positioned so that it discharges down the centre
line of the bath or across the opening of a shower cubicle.
11. The showerhead must be directed away from the shower unit, during normal
use the showerhead must not spray directly on to the shower unit.
12.
DO NOT
apply excessive force to plumbing connections; always provide
mechanical support when making plumbing connections. Any soldered joints
should be made before connecting the shower.
13. This shower is not designed to be plumbed directly from the rear. For rear-entry
supply, add an elbow to the supply pipe and connect as a rising or a falling
supply.
14. If pipework and/or electrical cables enter the shower from the rear through a
hole in the wall provision must be made to prevent water ingress back into the
wall structure.
15. Only use the inlet connector supplied with the shower.
DO NOT
use any other
type of fitting.
16. A full bore/non restrictive servicing valve must be fitted in a readily accessible
position adjacent to the shower to facilitate maintenance of the shower.
DO NOT
use a valve with a loose washer plate (jumper) as this can lead to a
build up of static pressure.