13
1493953-W2-A
1
2
3
4
5
Disconnect and remove the old
shower from the wall.
Isolate the electrical and water
supplies.
Position the Mira Sport Multi-fit
shower on the existing pipework.
Do not connect shower to pipe at
this point.
Note!
Use compression elbows
to connect rising and falling
supplies to the Right Inlet
Connector.
Remove the cover and service
tunnels from the Mira Sport
Multi-fit. Keep the retaining
screws (x3) for later use.
Screws
Service
Tunnel (RH)
Cover
Screw
Service
Tunnel (LH)
Rotate
inlet to
suit
Left Inlet Connector Configuration
Right Inlet Connector Configuration
Suitable for water
supplies from below
and the rear.
Position B
Rotate
inlet
to suit
Position A
Suitable for water
supplies from above,
below, from the right
and the rear.
Suitable for water supplies from
above, below and from the rear.
Adjust for RH water supply
and / or RH electricity supply if
required.