background image

32

1493953-W2-A

What to do if something goes wrong

If your product is not working correctly please refer 

to this manual for fault diagnosis and to check that 

it is installed and commissioned in accordance with 

our instructions. If this does not resolve the issue, 

our Customer Services team are here to help get you 

back up and running. To help us solve your problem 

quickly, please have your product name, power rating 

(if applicable) and date of purchase to hand.

Visit www.mirashowers.co.uk 

Visit our website to register your guarantee, book a 

service visit, diagnose faults and purchase products.

Spares and Accessories 

We stock a full range of spare parts and fi ttings and are 

all available to purchase either online or over the phone. 

Our online spare parts selector tool will help you quickly 

and easily identify the spare part for your product. 

Visit www.mirashowers.co.uk/parts-accessories

Replacements and Repairs 

In the unlikely event that your product needs a repair, 

our nationwide repairs and installation team are here to 

help. You can book a convenient date and time online. 

Scan the QR code to book a service visit 

now or visit www.mirashowers.co.uk/

support/repair-services/repair-service

We also off er a comprehensive replacement service 

for when your product needs a little refresh, visit our 

website or contact our team for more information on 

our replacement services.

Help us improve 

Your experience is important to us and your review 

(whether good, bad or otherwise) will be posted on 

Trustpilot.com immediately to help other people make 

more informed decisions.

Visit uk.trustpilot.com/review/www.mirashowers.co.uk

Mira is a registered trade mark 

of Kohler Mira Limited.

The company reserves the right 

to alter product specifi cations 

without notice.

EU Importer address

K/E S.A.S.

3 rue de Brennus,

93631, La Plaine Saint-Denis,

France

Registered Offi  ce: 

Cromwell Road,

Cheltenham, 

Gloucestershire 

GL52 5EP

14648

Guarantee 

Your  product  has  the  benefi t  of  our  manufacturer’s 

guarantee which starts from the date of purchase. 

This guarantee only applies in the United Kingdom 

and Republic of Ireland.

Activating Your Guarantee

Registering your guarantee is quick and simple. To 

ensure your product is covered, please register online .

Scan the QR code to activate your 

guarantee now or call 0800 5978551 

within 30 days of purchase (UK only).

 

What is Covered:

  ●  The  guarantee  applies  solely  to  the  original 

installation under normal use. 

  ●  The  product  must  be  installed  and  maintained 

in accordance with the instructions given in this 

guide.

  ●  Servicing must only be undertaken by us or our 

appointed representative.

  ●  Repair  under  this  guarantee  does  not  extend 

the original expiry date. The guarantee on any 

replacement parts or product ends at the original 

expiry date.

  ●  For  shower  fittings  or  consumable  items  we 

reserve the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such 

as damage or performance issues arising 

from incorrect installation, improper use, 

inappropriate cleaning, lack of maintenance, 

build up of limescale, frost damage, chemical 

attack, corrosion, system debris or blocked fi lters) 

or where no fault has been found with the product.

  ●  Water  or  electrical  supply,  waste  and  isolation 

issues.

  ●  Routine  maintenance  or  replacement  parts 

to  comply  with  the  requirements  of  Building  / 

Plumbing / Electrical Standards or Schemes.

  ●  Compensation for loss of use of the product or 

consequential or indirect loss of any kind. 

  ●  Damage  or  defects  caused  if  the  product  is 

repaired or modifi ed by persons not authorised 

by us or our appointed representative.

  ●  Accidental or wilful damage. 

  ●  Products purchased ex-showroom display.

  ●  Disinfection  or  descaling  to  reduce  bacterial 

growth or contamination.

Need to get in touch? 
UK

T: 0800 001 4040

E: [email protected]

www.mirashowers.co.uk

Eire

T: 01 531 9337

E: [email protected]

www.mirashowers.ie

1473739-W6-A

© Kohler Mira Limited, September 2021

Customer Support

Содержание Mira Sport Multi-fit 1.1746.009

Страница 1: ...1 1493953 W2 A These instructions must be left with the user Mira Sport Multi fit 9 0 and 9 8 kW Installation and User Guide For SPARES ADVICE or REPAIRS please call us free on 0800 001 4040 UK only ...

Страница 2: ...uction concerning use of the appliance in a safe way and understand the hazards involved 2 Children shall not be allowed to play with the shower 3 DO NOT restrict the water flow from the shower outlet temporarily bending the shower hose or blocking the shower head while in use can cause a hot shot of water to be discharged 4 Cleaning and user maintenance shall not be made by children without super...

Страница 3: ...et mode point handset away from body and make sure that the water temperature has stabilised before continuing to shower 16 Use caution when altering the water temperature always check the temperature before continuing to shower 17 Switch the shower off at the electrical isolating switch when not in use This is recommended with all electrical appliances 18 Installation of the shower must be carrie...

Страница 4: ... safe before entering the shower 26 The water supplies to this product must be isolated if the product is not to be used for a long period of time If the product or pipework is at risk of freezing during this period they should also be drained of water 27 If the shower is dismantled during installation or servicing then upon completion an inspection must be made to ensure all electrical connection...

Страница 5: ... 3 x Fixing Screws 1 x Olive 5 x Case Inserts 1 x Mira Sport Multi fit Electric Shower INLET CONNECTOR TERMINAL BLOCK HEATER TANK MICRO SWITCH L MICRO SWITCH R SOLENOID LED LED HOUSING PUSHBUTTON SWITCH BROWN B GREEN D BLUE C RED K BROWN J BROWN G BLACK M BLACK L RED H BLUE E BROWN F B L U E E BLACK N GREEN A GREEN A GREEN D Documentation 1 x Installation Template 1 x Installation User Guide 1 x G...

Страница 6: ...er in accordance with our instructions and recommendations Follow all warnings cautions and instructions contained in this guide and on or inside the shower Mira Sport Multi fit electric showers have separate controls for power selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps be...

Страница 7: ...00 ppm CaCO3 Outlet Connection 1 2 BSP Male Electrical Multi fit Variant 9 0 9 8 Nominal Power at 230 V ac 8 3 kW 9 0 kW Nominal Power at 240 V ac 9 0 kW 9 8 kW Recommended MCB Rating 40 A 45 A Maximum Supply Cable Size 16 mm Recommended RCD Rating 30 mA tripping current Recommended Isolator Switch 45 A double pole with 3 mm contact separation Appliance Sealing Rating IP X4 Suitable for installati...

Страница 8: ... are subject to conditional connection If the main electrical supply fuse is rated less than 80Amps the local electricity supply company must be contacted to confirm if the electrical supply is adequate The Mira Sport Multi fit range of showers complies with the requirements of the UK s water regulations Disposal and Recycling End of Product Life Electrical and electronic devices contain a range o...

Страница 9: ...erproof flat and even wall surface 8 DO NOT fit the shower to the wall and tile up to the case 9 DO NOT seal the gap between the shower and the wall surface 10 The showerhead should be positioned so that it discharges down the centre line of the bath or across the opening of a shower cubicle 11 The showerhead must be directed away from the shower unit during normal use the showerhead must not spra...

Страница 10: ...l installation until the plumbing has been completed and checked for leaks Hose retaining ring fitted and shower fittings fixed at a suitable height preventing dirty water backflow Note There will be occasions when the hose retaining ring will not provide a suitable solution for Fluid Category 3 installations in these instances an outlet double check valve must be fitted this will increase the req...

Страница 11: ...rom the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provided with means for local disconnection that is incorporated into the fixed wiring in accordance with the relevant local wiring regulations This must be a double pole switch which has at least 3 mm contact separation in each pole The switch...

Страница 12: ... supply position is set for left hand entry if the installation favours right hand entry the LH inlet filter coloured black and RH inlet connector plug coloured red must be exchanged Go to Adjustment for right hand entry water supplies Rising Rear fed water supplying left hand Inlet Connector Rear fed water supplying right hand Inlet Connector Falling Rotate inlet to suit Rotate inlet to suit Elec...

Страница 13: ...er and service tunnels from the Mira Sport Multi fit Keep the retaining screws x3 for later use Screws Service Tunnel RH Cover Screw Service Tunnel LH Rotate inlet to suit Left Inlet Connector Configuration Right Inlet Connector Configuration Suitable for water supplies from below and the rear Position B Rotate inlet to suit Position A Suitable for water supplies from above below from the right an...

Страница 14: ...the supplied wall plugs Caution Do not drill into buried pipes or cables Caution Do not drill into buried cables or pipes Go to Connecting Electricity and Water Supplies to complete the installation Left side electrical cable entry shown Feed the electrical cable in through the back of the shower and make sure the wires will connect adequately to the terminal block ...

Страница 15: ...e terminal block is repositioned on the right hand side the retaining screw must be fitted to the hole on the left side of the terminal block Check the wiring and ensure that it has not been damaged and will not be trapped Retaining Screw Terminal block default location Terminal block alternative location Note position of retaining screw Unscrew the terminal block retaining screw Carefully lift th...

Страница 16: ...to the right hand inlet connector and tighten with the wrench support the connector whilst tightening Repeat the procedure to refit the inlet plug to the LH inlet connector Follow the same procedure to remove the inlet filter from the LH inlet connector 5 6 Isolate the electrical and water supplies Inlet Filter coloured black Inlet Plug coloured red This completes the adjustment for right hand ent...

Страница 17: ...cable size Refer to BS 7671 Do not drill into buried cables or pipes 1180327 W7 A Kohler Mira Limited July 2011 Mira Sport Multi fit Attention Installer Do not install the appliance where it may become frozen Avoid dust contamination of the appliance by using this template to mark and drill into the wall Drill appliance case separately Do not drill into buried cables or pipes Do not use alternativ...

Страница 18: ...ing Right Inlet Connector Suitable for water supplies from below and the rear Position B Rotate inlet to suit Position A Suitable for water supplies from above below from the right and the rear Suitable for water supplies from above below and from the rear 2 Connecting Electricity and Water Supplies 1 Thoroughly flush the supply pipe Connect the inlet supply pipe to the inlet connector using one o...

Страница 19: ...ctor Inlet Supply Compression Nut Compression Nut 1 2 BSP Nipple Right Inlet Connector use a 1 2 BSP nipple with compression nuts or 1 2 BSP elbow 6 7 N Neutral Blue wire L Live Brown wire Protective Earth Green Yellow sleeved wire Strip back sufficient outer cable insulation to enable routing to the terminal block Fit an earth sleeve to the earth wire if required 8 9 Ensure that all wires are sec...

Страница 20: ...off sections of the inserts to suit incoming electrical or water supplies before fitting Ensure the control dials are aligned with the spindles and replace the cover Tighten the three cover screws Do not use alternative screws to secure the cover This can cause internal damage to the appliance Do not seal around the back of appliance This completes the installation follow the guidelines in section...

Страница 21: ...P button Light in the button illuminates Water flows freely within a few seconds temperature remains cool Slowly turn the temperature control to the hot position Turn temperature control back to the midway position Flow is reduced and temperature remains cool TEMPERATURE TEMPERATURE LOW HIGH ECO POWER TEMPERATURE 1 3 2 4 6 5 8 7 COLD 0 15 secs HOT COLD HOT ...

Страница 22: ...Temperature will rise further Turn power control to Eco Temperature will rise slightly Adjust temperature as required Flow rate will adjust automatically Push START STOP button Light in the button goes out Switch off the electrical supply The shower will purge water from its tank for a few seconds LOW HIGH ECO POWER LOW HIGH ECO POWER TEMPERATURE 9 10 11 12 13 14 15 16 5 10 secs COLD HOT 5 10 secs...

Страница 23: ...s for any temperature adjustments to stabilise and reach the showerhead Check the water temperature before entering shower Switch off the electrical supply Push the START STOP button to turn ON the appliance Light in the button illuminates Push START STOP button Light in the button goes out and shower continues to run for a few seconds Operation LOW HIGH ECO POWER POWER TEMPERATURE TEMPERATURE 1 2...

Страница 24: ...rature of the shower therefore the shower temperature may need to be increased or decreased to maintain the desired showering temperature For a cold shower select LOW For a summer warm shower select ECO HIGH For a winter warm shower select HIGH Adjust the temperature as required The flow rate will adjust automatically LOW HIGH ECO LOW HIGH ECO LOW HIGH ECO COLD HOT 9 Water inlet pressure fluctuati...

Страница 25: ...l mounted switch Renew the fuse or reset the MCB RCD If fault persists contact your installer Check case inserts are cut and fitted correctly Check services electrical or plumbing are not interfering with location of service tunnel or cover Shower cycles from hot to cold ON ECO HIGH Showerhead blocked Hose kinked or blocked Water pressure below minimum required for shower operation Temperature con...

Страница 26: ...Showerhead blocked Hose kinked or blocked Other outlets e g toilet garden hose washing machine etc drawing water while the shower is being used Flush supply pipe Clean inlet filter Contact local water company Supply pressure must be a minimum of 70 kPa 0 7 bar Note If other appliances are operating pressure may drop below 70 kPa 0 7 bar Replace flow valve Replace heater tank In hard water areas co...

Страница 27: ...top switch faulty Replace as necessary Shower fails to produce hot water when set on Eco High setting ON ECO HIGH Insufficient water supply Possible failure of the microswitch or thermal switch Contact local water company Use a suitable device to check the continuity of the microswitch or heater tank and replace parts as necessary Water leaks from the bottom of the case and there is no flow from t...

Страница 28: ...lear or inspect the hose for blockage or internal external collapse can restrict the flow rate from the shower This may cause damage to the shower or result in the temperature delivered to the user rising to unsafe levels with a risk of scalding You MUST ALWAYS check the temperature before using the shower Use your thumb or a soft cloth to wipe any limescale from the soft nozzles Unscrew the hose ...

Страница 29: ...ying cause of the malfunction has been resolved Remove the three screws that hold the cover on the shower and remove the cover Cleaning the Inlet Filter Warning Isolate the electrical and water supplies before removing the cover 1 2 Service Tunnel LH Service Tunnel RH Screw Cover Screws Remove the service tunnels from the shower 3 Determine the direction and route of the incoming water supply Left...

Страница 30: ...opriate inlet connector assembly Hold a wrench across the flats of the inlet connector assembly to prevent damage to the connector whilst removing the filter Refit the components in reverse order Remove the filter and rinse under a running tap to remove any lodged particles If necessary use a kettle descalent in accordance with the manufacturer s instructions Inlet Filter ...

Страница 31: ...l Switch 1746 502 Outlet Connector B B B 1746 500 Flow Valve 1746 571 Screw Pack identified A 1746 505 Component Pack identified B 1746 507 Case Cover Seal not shown 1746 550 Wire Pack not shown 1746 506 Terminal Block 1746 496 Inlet Connector 1746 499 Inlet Clamp 1746 497 Inlet Assembly 1746 498 Inlet Manifold 1746 503 Service Tunnel 1746 504 Service Tunnel RH A A A A A A A A A A A A A 1746 499 I...

Страница 32: ...tenham Gloucestershire GL52 5EP 14648 Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase This guarantee only applies in the United Kingdom and Republic of Ireland Activating Your Guarantee Registering your guarantee is quick and simple To ensure your product is covered please register online Scan the QR code to activate your guarantee now ...

Отзывы: