19
1493953-W2-A
3
4
Secure the shower to the wall
with the supplied screws.
If the water inlet is rear fed,
make sure the elbow fitting
can be removed to allow any
future maintenance (cleaning the
filter etc.) to be performed. See
section
"SERVICING - Cleaning
the Inlet Filter"
.
Turn on the water supply and
check for leaks.
5
Inlet Connector
Compression Nut
Compression Nut
Inlet Supply
Olive
Olive
1/2’’ BSP Nipple
Right Inlet Connector
Olive
Olive
Inlet Connector
Inlet Supply
Compression Nut
Compression Nut
1/2" BSP Nipple
Right Inlet Connector -
use a
1/2" BSP nipple with compression
nuts or 1/2" BSP elbow.
6
7
N
(Neutral) = Blue wire
L
(Live) = Brown wire
(Protective Earth) =
Green /Yellow sleeved wire
Strip back sufficient outer cable
insulation to enable routing to the
terminal block. Fit an earth sleeve
to the earth wire if required.
8
9
Ensure that all wires are secure
and all 6 screws are tight.
Ensure the earth bonding complies
with relevant regulations.
cont...
Insert the wires into the terminal
block connections and tighten
the screws.
For rear fed supplies always
allow enough room for
maintenance to be performed.