![Kohler K-10970 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/kohler/k-10970/k-10970_homeowners-manual_1987984007.webp)
Remove the DC Sensor or Sensor Clip
NOTE:
Replacement batteries can be purchased from drugstores.
The battery is a 6.0 volt 1300 mAh Lithium battery with model
numbers of 2CR5, DL245, EL2CR5, KL2CR5, or 2CR5M.
Perform the following steps to remove the DC sensor and battery:
Close the control stop valve (refer to the
″
Control Stop Valve
Operations
″
section).
Using the supplied hex head wrench, remove the screw from the
valve cap.
Remove the cap by lifting from the valve body.
Disconnect the plug to the solenoid by pulling the connectors
apart.
Position the cap on its side and look inside.
Using needle nosed or equivalent tool, grasp the plastic clip that
holds the DC sensor in place in the cap.
Pull the clip from the cap.
Turn the cap over and slide the sensor into your hand.
NOTE:
The lithium battery inside the sensor may be considered
hazardous waste. Discard the old sensor in accordance with any
applicable codes.
If replacing the DC sensor, discard the old DC sensor and battery.
Cap Assy
Screw
DC Sensor
Clip
Kohler Co.
7
1025497-5-B