MDC-7000P/7900P Series
Chapter 5 Troubleshooting and on board repair
0092669006-05E
5-7
No off center.
In the maximum range, off center function was
disabled.
Tracking malfunction. BRG T
As the result of TT test, the accuracy of bearing
has exceeded the reference.
Tracking malfunction. RNG
As the result of TT test, the accuracy of range
has exceeded the reference.
Tracking malfunction. CPA
As the result of TT test, the accuracy of CPA
has exceeded the reference.
Tracking malfunction. TCPA
As the result of TT test, the accuracy of TCPA
has exceeded the reference.
Tracking malfunction. T CRS
As the result of TT test, the accuracy of true
course has exceeded the reference.
Tracking malfunction. T SPD
AS the result of TT test, the accuracy of true
speed has exceeded the reference.
Mode hold.
Attemted to change mode during operation of
performance monitor. The mode is fixed at
H-UP.
Range hold.
During starting up of performance monitor,
attempted to change the range. The range is
fixed at 24 NM.
Time to trial manoeuvre is less than 30 seconds.
The remaining time of trial manoeuvre is less
than 30 seconds.
Reference target overload.
Attempted to acquire reference target beyond 3.
Do not use MAN COG/SOG.
Cannot use AIS with COG/SOG data inputted
by manual.
Do not use REF COG/SOG.
Cannot use AIS with COG/SOG data calculated
by reference target.
Do not use CURRENT COG/SOG.
Cannot use AIS with SET/DRIFT data inputted
by manual.
Do not use MAN STW.
Cannot use AIS with speed data inputted by
manual.
Do not use MAN POSITION.
Cannot use AIS with own ship position data
inputted by manual.
Time error.
Cannot use AIS with no time data.
Do not use MAN OFFSET POSITION.
Cannot use AIS with offset positon inputted by
manual.
Содержание MDC-7000P series
Страница 1: ......
Страница 2: ......
Страница 40: ...Chapter 3 Installation Method MDC 7000P 7900P Series 3 18 0092669006 05E Unit mm inch MRM 108P ...
Страница 56: ... This page intentionally left blank ...
Страница 90: ... This page intentionally left blank ...
Страница 116: ... This page intentionally left blank ...
Страница 146: ... This page intentionally left blank ...
Страница 147: ...0092669006 05E A 1 INTER CONNECTION DIAGRAM RB808P ...
Страница 148: ...A 2 0092669006 05E INTER CONNECTION DIAGRAM RB809P ...
Страница 149: ...0092669006 05E A 3 INTER CONNECTION DIAGRAM MRD 108P MRO 108P ...
Страница 150: ...A 4 0092669006 05E INTER CONNECTION DIAGRAM MRM 108P MRO 108P ...
Страница 151: ......
Страница 152: ......