Chapter 3 Installation Method MDC-7000P/7900P
Series
3-30
0092669006-05E
3.4.6 AIS cable connection
The AIS connected with radar must be compliant with the resolution A.917 (22).
*Green/Black twisted cable (Black is not used.)
1
7
2
3
4
8
6
5
Pin
No.
CW-387 Wire color Signal name
1 Shield
Frame
ground
2
Blue
Twist
cable
IN-A
3 White
IN-B
4
Yellow
Twist
cable
OUT-B
5 Brown
OUT-A
6
Green*
GND
7
Red
Twist
cable
NC
8 Grey
NC
Pin 1 Indicated
AIS Cable connector pin assignment
Serial signal
IEC 61162-2
CW-387-5M
J2
Figure 3.19 AIS cable connection