Chapter 3 Installation Method MDC-7000P/7900P
Series
3-24
0092669006-05E
3.3.2.1 Flush mounting the Operation unit
Preparation:
(1)
Cut an opening as shown in Figure 3.11 in desired location on a panel.
(2)
Mark position of mounting holes.
(4mm screw for 4holes)
(15/32)
12
(5 3/64)
128
(4 5/64)
122
(15/32)
12
(12 33/64)
318
(15/32)
12
(13 15/32)
342
(3 55/64)
98
(13 45/64)
348
Unit : mm(inch)
Installation:
(1) Remove corner guard caps of Operation unit.
(2) Insert the Operation unit and its connecting cable into the opening and adjust the Operation
unit parallel to the mounting face (Figure 3.12).
(3) Secure the Operation unit to the panel with 4 mm tapping screw (4 places).
(4) Reinstall corner guard caps removed in (1) to the original places.
Figure 3.11 Cutout Daigram for Operation unit
(4 51
/64
)
Figure 3.12 Flush Mounting of the Operation unit
Note: Panel thickness: 10 mm (max)
Corner guard cap
(4 places)
M4 screw
(4 places)
Operation unit
Содержание MDC-7000P series
Страница 1: ......
Страница 2: ......
Страница 40: ...Chapter 3 Installation Method MDC 7000P 7900P Series 3 18 0092669006 05E Unit mm inch MRM 108P ...
Страница 56: ... This page intentionally left blank ...
Страница 90: ... This page intentionally left blank ...
Страница 116: ... This page intentionally left blank ...
Страница 146: ... This page intentionally left blank ...
Страница 147: ...0092669006 05E A 1 INTER CONNECTION DIAGRAM RB808P ...
Страница 148: ...A 2 0092669006 05E INTER CONNECTION DIAGRAM RB809P ...
Страница 149: ...0092669006 05E A 3 INTER CONNECTION DIAGRAM MRD 108P MRO 108P ...
Страница 150: ...A 4 0092669006 05E INTER CONNECTION DIAGRAM MRM 108P MRO 108P ...
Страница 151: ......
Страница 152: ......