Chapter 4 Setup after installation MDC-7000P/7900P
Series
4-28
0092669006-05E
(1) Set range scale 3 NM.
(2) Press MENU key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [GAIN OFFSET] => increase setting value.
(3) Change range scale up and down to check the gain sensitivity difference.
Setting value is 0 to 4095: Initial setting is 0.
Note: This function is effective about the change of the transmission pulse width.
4.5.5 Setup SEA OFFSET mode
This is a function to adjust the sea clutter suppression difference of every range when range scale is
changed.
This setting is performed by every each range scale.
For example: When sea clutter suppression of 3NM looks low (weak).
(1) Set range scale 3NM.
(2) Press MENU key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [SEA OFFSET] => increase setting value.
(3) Change range scale up and down to check the sea clutter suppression difference.
Setting value is 0 to 4095: Initial setting is 0.
Note: This function is effective about the change of the transmission pulse width.
4.6 BACKUP of Setup data (Cannot be used while transmitting)
By saving setup data to the internal memory or external memory, the initial setup and all settings are
saved, in the event that the radar needs to be reinitialized or some changes been made, user can go
back to the original settings by restoring from memory.
Backup of setup data should be saved after initial setup.
In case of malfunction of display where initialization must be done, restore of backup data saved at the
time of original setup will bring all proper settings and turning setup back to normal operation.
4.6.1 Internal save of setup data
Save setup data to the internal memory:
(1) Press MENU key to display “Menu”.
Select [MAINTENANCE] => [BACKUP] => [SETUP SAVE] => [GO], and press ENT key.
Restore setup data from the internal memory:
(1) Press MENU key to display “Menu”.
Select [MAINTENANCE] => [BACKUP] => [SETUP LOAD] => [GO], and press ENT key.
Содержание MDC-7000P series
Страница 1: ......
Страница 2: ......
Страница 40: ...Chapter 3 Installation Method MDC 7000P 7900P Series 3 18 0092669006 05E Unit mm inch MRM 108P ...
Страница 56: ... This page intentionally left blank ...
Страница 90: ... This page intentionally left blank ...
Страница 116: ... This page intentionally left blank ...
Страница 146: ... This page intentionally left blank ...
Страница 147: ...0092669006 05E A 1 INTER CONNECTION DIAGRAM RB808P ...
Страница 148: ...A 2 0092669006 05E INTER CONNECTION DIAGRAM RB809P ...
Страница 149: ...0092669006 05E A 3 INTER CONNECTION DIAGRAM MRD 108P MRO 108P ...
Страница 150: ...A 4 0092669006 05E INTER CONNECTION DIAGRAM MRM 108P MRO 108P ...
Страница 151: ......
Страница 152: ......