![Koden MDC-7000P series Скачать руководство пользователя страница 98](http://html.mh-extra.com/html/koden/mdc-7000p-series/mdc-7000p-series_installation-manual_1984781098.webp)
Chapter 5 Troubleshooting and on board repair
MDC-7000P/7900P Series
5-8
0092669006-05E
5.3 Malfunction diagnostics
This chapter specifies necessary information required troubleshooting and repair of the radar system.
5.3.1 Malfunction detection step
As a first step of on board repair, refer to the following tables describing outlines of malfunction
diagnostics procedure.
Table 5.3 basic malfunctions
Failure status
Possible cause
Measure
No power.
1. Power cable is disconnected.
2. Operation unit cable is
disconnected.
3. Supply voltage is out of range.
4. Main power fuse is blown.
1. Connect power cable firmly
and secure connector.
2. Connect operation cable
firmly and secure connector.
3. Use proper power source.
4. Change fuse with new one.
Power is applied but no
display
1. Display brilliance is adjusted to the
minimum.
2. Connector of internal cable is
disconnected.
3. Failure of LCD unit or Backlight
power PCB
1. Adjust
properly.
2. Confirm by a serviceman.
3. Request
repair.
Table 5.4 possible malfunctions
Error status
Possible cause
Measure
Display brilliance is
dark.
1. Adjustment of display brilliance is
incorrect.
2. Failure of LCD driver circuit
3. Failure of Backlight power PCB
1. Adjust
properly.
2. Request
repair
3. Request
repair
No radar echo is
displayed.
1. Receiver is detuned.
2. Video contrast adjustment error
3. Failure of transceiver
1. Adjustment”.
2. Readjust by referring to “4.2.1
Tune adjustment”.
3. Request
repair
Radar echo is too weak. 1. Receiver is detuned.
2. Failure of Magnetron or MIC
(front-end)
1. Readjust by referring to “4.2.1
Tune adjustment”.
2. Request
repair
Error message “Head
line signal abnormal.” is
displayed.
1. No heading line signal input.
1. Check [BP/HG] signal
between an Antenna Scanner
unit and a Display unit.
Antenna does not
rotate.
1. Motor fuse is blown.
2. Motor power is not supplied.
3. Inter-switch mode is difference.
1. Replace fuse with a new one.
2. Check
motor
power
connection.
3. Set inter-switch mode to
master mode.
Содержание MDC-7000P series
Страница 1: ......
Страница 2: ......
Страница 40: ...Chapter 3 Installation Method MDC 7000P 7900P Series 3 18 0092669006 05E Unit mm inch MRM 108P ...
Страница 56: ... This page intentionally left blank ...
Страница 90: ... This page intentionally left blank ...
Страница 116: ... This page intentionally left blank ...
Страница 146: ... This page intentionally left blank ...
Страница 147: ...0092669006 05E A 1 INTER CONNECTION DIAGRAM RB808P ...
Страница 148: ...A 2 0092669006 05E INTER CONNECTION DIAGRAM RB809P ...
Страница 149: ...0092669006 05E A 3 INTER CONNECTION DIAGRAM MRD 108P MRO 108P ...
Страница 150: ...A 4 0092669006 05E INTER CONNECTION DIAGRAM MRM 108P MRO 108P ...
Страница 151: ......
Страница 152: ......