MDC-7000P/7900P Series
Chapter 4 Setup after installation
0092669006-05E
4-23
(3) Press MENU key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [RAIN MAX] and highlight the last digit of the numerical
entry frame.
(4) Move the trackball up and down to change watching the display, and press ENT key when large
blocks of rain clutter become smaller points and just before small boats and seaway buoys will
disappear.
Setting value is 0 to 4095: Initial setting is 0
CFAR mode
(1) Check CFAR indication of RAIN mode from upper right of the display. If RAIN mode is MAN,
change to CFAR mode. If SEA mode is AUTO, change to MAN mode.
(2) Set RAIN at 100 by turning RAIN knob and set SEA at 0 by turning SEA knob in rainfall.
(3) Press MENU key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [RAIN MAX] and highlight the last digit of the numerical
entry frame.
(4) Move the trackball up and down to change watching the display, and press ENT key when large
blocks of rain clutter become smaller points and just before small boats and seaway buoys will
disappear.
Setting value is 0 to 4095: Initial setting is 4095
4.5.2 Setup SEA MIN and MAX mode
There are two modes of MAN and AUTO in sea clutter suppression.
Change method of MAN and AUTO.
Press the SEA knob, or put a cursor on the indicator of MAN or AUTO upper right of the display and
press ENT key.
4.5.2.1 SEA MIN (MAN and AUTO mode)
This setting is a function to make the value set under Sea suppression effective even when SEA is set
at a minimum level by turning SEA knob. Due to the raise of the minimum value, this function allows the
effect against the angle of the turning of the knob to be moderated and the adjustment with the knob to
be made easier. This adjustment can be used in common for the entire range. Please carry out the
adjustment at mild state of sea.
MAN mode
(1) Check MAN indication of SEA mode from upper right of the display. If SEA mode is AUTO, change
to MAN mode. If GAIN mode is AUTO, change to MAN mode. If RAIN mode is CFAR, change to
MAN mode.
Содержание MDC-7000P series
Страница 1: ......
Страница 2: ......
Страница 40: ...Chapter 3 Installation Method MDC 7000P 7900P Series 3 18 0092669006 05E Unit mm inch MRM 108P ...
Страница 56: ... This page intentionally left blank ...
Страница 90: ... This page intentionally left blank ...
Страница 116: ... This page intentionally left blank ...
Страница 146: ... This page intentionally left blank ...
Страница 147: ...0092669006 05E A 1 INTER CONNECTION DIAGRAM RB808P ...
Страница 148: ...A 2 0092669006 05E INTER CONNECTION DIAGRAM RB809P ...
Страница 149: ...0092669006 05E A 3 INTER CONNECTION DIAGRAM MRD 108P MRO 108P ...
Страница 150: ...A 4 0092669006 05E INTER CONNECTION DIAGRAM MRM 108P MRO 108P ...
Страница 151: ......
Страница 152: ......