Max inc. in 1 sample:
Specifies the maximum positive injection compensation
between two samples as a percentage. If 0.0 is set in
here this function is not active.
For example: if the sample rate is set on 10 samples
per second. The maximum increase in 1 sample is set on 0.5. Then the lambda control can only
compensate 10 x 0.5 = 5% fuel increase per second.
Max dec. in 1 sample:
Specifies the maximum negative injection compensation between two samples as a percentage. If 0.0
is set in here this function is not active.
For example: if the sample rate is set on 10 samples per second. The maximum decrease in 1 sample
is set on 0.5%. Then the lambda control can only compensate 10 x 0.5 = 5% fuel decrease per
second.
Up to main load <:
Above this main load value, there is no limit on the compensation between two samples. If 0.0 is set in
here this function is not active.
Recommended is to set this value after the engine is properly mapped, and to a value of 4.0 - 6.0.