Operating hours
The
operating hours
of the device in
different operating states (
Label
) are
displayed under
DEV_1
–
DEV_4
.
Error list/Error codes
The error list shows
Timestamp
(operating hours) and
Severity
(CRITICAL,
WARNING, INFO) and the number of the
Error code
with a
Description
, see table
below.
Error code Description
-120
Power Supply Voltage too low
-121
Power Supply Voltage too high
-123
Temperature Monitoring: Information: LightEngine hot
-124
Temperature Monitoring: Warning: LightEngine too hot; reducing light output
-125
Temperature Monitoring: Error: LightEngine temperature limit exceeded
-126
Temperature Monitoring: LightEngine temperature sensor data missing
-127
Temperature Monitoring: Information: MainBoard hot
-128
Temperature Monitoring: Warning: MainBoard too hot; reducing light output
-129
Temperature Monitoring: Error: MainBoard temperature limit exceeded
-130
Temperature Monitoring: MainBoard temperature sensor data missing
-131
Optosensor data missing (sensor not responding)
-132