49
4
Quadrant
Energy Analyzer
4
Quadrant
Energy Analyzer
SECTION 3 MENUS
Settings->Setup->Analog output->Output1
Input mode
V1 (L-N)
Output conn.
0-5V
Min. value
0.0
Max. value
0.0
Multiplier
1
V1 (L-N)
V2 (L-N)
V3 (L-N)
I1
I2
I3
P1
P2
P3
Q1
Q2
Q3
Fig. 3-39 Input mode
3.2.1.1.6.1.2 Output connection
Inside Output1 menu, press up and down keys to select (highlight) ‘Output connection’
menu item. When‘Output connection’ is selected, press OK key and the options in
will appear on the screen. Press up and down keys to select the desired option
and press OK key to complete the setting.
Settings->Setup->Analog output->Output1
Input mode
V1 (L-N)
Output conn.
0-5V
Min. value
0.0
Max. value
0.0
Multiplier
1
0 - 5V
0 - 10V
-5 - 5V
-10 - 10V
0 - 20mA
4 - 20mA
Fig. 3-40 Output connection
Assume that for analog output 1, output connection was selected as 0-5V
( Refer to
. Then, operator should adjust the“analog output 1”dip switch as seen in
(Vout1 -> ON ; Iout1 -> OFF). After the dip switch adjustment, setting will be completed.
OFF
ON
IO
ut4
VO
ut4
IO
ut3
VO
ut3
IO
ut2
VO
ut2
IO
ut1
VO
ut1
Fig. 3-41 Vout1 -> ON; Iout1 -> OFF
Содержание Klea 320P-D
Страница 1: ...1 4Quadrant Energy Analyzer 1 KLEA Network Analyzer User Manual 4Quadrant Energy Analyzer...
Страница 8: ...8 4Quadrant Energy Analyzer SECTION 1 GENERAL INFORMATION 4Quadrant Energy Analyzer...
Страница 14: ...14 4Quadrant Energy Analyzer SECTION 2 INSTALLATION 4Quadrant Energy Analyzer...
Страница 21: ...21 4Quadrant Energy Analyzer SECTION 3 MENUS 4Quadrant Energy Analyzer...
Страница 82: ...82 4Quadrant Energy Analyzer SECTION 4 MODBUS PROTOCOL 4Quadrant Energy Analyzer...
Страница 119: ...119 4Quadrant Energy Analyzer SECTION 5 FACTORY DEFAULT SETTINGS 4Quadrant Energy Analyzer...
Страница 123: ...123 4Quadrant Energy Analyzer SECTION 6 TECHNICAL SPECIFICATIONS 4Quadrant Energy Analyzer...