39
4
Quadrant
Energy Analyzer
4
Quadrant
Energy Analyzer
3.2.1.1.3.12 T2 kWh
“Initial” value for meter of “ Imp. Active=>T2” can be entered in this tab.
3.2.1.1.3.13 T2 kWh E.
“Initial” value meter of “ Exp. active=>T2” can be entered in this tab.
3.2.1.1.3.14 T2 kVArh Imp. I.
“Initial” value for meter of “Reactive R1=>T2” can be entered in this tab.
3.2.1.1.3.15 T2 kVArh Imp. C.
“Initial” value for meter of “Reactive R2=>T2” can be entered in this tab.
3.2.1.1.3.16 T2 kVArh Exp. I.
“Initial” value for meter of “Reactive R2=>T2” can be entered in this tab.
3.2.1.1.3.17 T2 kVArh Exp. C.
“Initial” value for meter of “Reactive R4=>T2” can be entered in this tab.
NOTE:
“T1 rate1”, “T1 rate2” ve “T1 rate3” is made from "Settings => Setup => Energy"
menu. These appointments should be made using Modebus communications over
the computer. Energy value that will be assigned, must be written to corresponding
modebus address. Related ModeBus addresses are given below. For more information
refer to “
2032. modebus address:“Initial “energy value for meter of “Imp. active => T1 rate1” can be entered.
2034. modebus address:“Initial “energy value for meter of “Exp. active => T1 rate1” can be entered.
2036. modebus address:“Initial “energy value for meter of “Reactive R1 => T1 rate1” can be entered.
2038. modebus address:“Initial “energy value for meter of “Reactive R2 => T1 rate1” can be entered.
2040. modebus address:“Initial “energy value for meter of “Reactive R3 => T1 rate1” can be entered.
2042. modebus address:“Initial “energy value for meter of “Reactive R4 => T1 rate1” can be entered.
2044. modebus address:“Initial “energy value for meter of “Imp. active => T1 rate2” can be entered.
2046. modebus address:“Initial “energy value for meter of “Exp. active => T1 rate2 can be entered.
2048. modebus address:“Initial “energy value for meter of “Reactive R1 => T1 rate2” can be entered.
2050. modebus address:“Initial “energy value for meter of “Reactive R2 => T1 rate2” can be entered.
2052. modebus address:“Initial “energy value for meter of “Reactive R3 => T1 rate2” can be entered.
SECTION 3 MENUS
Содержание Klea 320P-D
Страница 1: ...1 4Quadrant Energy Analyzer 1 KLEA Network Analyzer User Manual 4Quadrant Energy Analyzer...
Страница 8: ...8 4Quadrant Energy Analyzer SECTION 1 GENERAL INFORMATION 4Quadrant Energy Analyzer...
Страница 14: ...14 4Quadrant Energy Analyzer SECTION 2 INSTALLATION 4Quadrant Energy Analyzer...
Страница 21: ...21 4Quadrant Energy Analyzer SECTION 3 MENUS 4Quadrant Energy Analyzer...
Страница 82: ...82 4Quadrant Energy Analyzer SECTION 4 MODBUS PROTOCOL 4Quadrant Energy Analyzer...
Страница 119: ...119 4Quadrant Energy Analyzer SECTION 5 FACTORY DEFAULT SETTINGS 4Quadrant Energy Analyzer...
Страница 123: ...123 4Quadrant Energy Analyzer SECTION 6 TECHNICAL SPECIFICATIONS 4Quadrant Energy Analyzer...