6. Troubleshooting
a.) If the pump doesn’t reach the final operating pressure air may have penetrated the
system.
=>
Hold the crimping head lower than the electric pump and actuate the foot switch
(Pos.-No. 7) until the dies have contacted each other. Repeat this procedure 2 or 3
times.
If the pump is still not reaching the full pressure repeat this process again until the
pump works properly.
Should the malfunction not be corrected by this operation the pump must be returned to
the
manufacturer.
b.) The pump loses oil.
=>
Return the tool to the manufacturer. Do not open or destroy the seals of the tool.
7. Putting out of service/waste disposal
After many years of intensive use even a high quality tool has finally to be put out of service.
The disposal of the various components of the tool have to be treated separately. The first step
is to dispose of the oil at special delivery points.
Attention
Hydraulic oils represent a danger for the ground water. Uncontrolled draining of
oil or improper disposal is under penalty of applicable environmental liability
laws.
Next dismantle the high-pressure hose and dispose of the oil in the hose with the oil in the
pump. The emptied hose needs also to be disposed of at a special delivery point.
For the dispose of the remaining parts of the unit reference your domestic environmental
laws.
Because of possible environmental damages we recommend the disposal of the tool by
professional companies. A return of the old unit free of charge to the manufacturer cannot be
granted.