3-3
Electrical Shock Hazard
Disconnect the electrical supply from the
unit before servicing.
Failure to do so could result in death or
electrical shock.
WARNING
TEST PROCEDURE
Refer to page 2-20 for the procedure for ser-
vicing the blower motor.
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R X 1 scale.
3.
Disconnect the wires from the blower
motor’s terminals.
4.
Touch the test leads to the motor termi-
nals. The ohmmeter should indicate 14 to
18
Ω
.
Motor
Terminals
Resistance Test (At The Electronic
Range Control)
NOTE: To test the blower motor at the elec-
tronic range control, perform the following steps
(see page 2-4 for removing the top access
panel).
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R x 100 scale.
3.
Disconnect the P1-1 wire (gray) connector
and the neutral (white) wire from the elec-
tronic range control.
4.
Touch the ohmmeter test leads to the gray
and white wires. The ohmmeter should
indicate 14 to 18
Ω
.
BLOWER MOTOR