3-2
TEST PROCEDURE
Refer to page 2-4 for the procedure for servic-
ing the control power and lamp transformers.
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R X 1 scale.
3.
Disconnect the wires from the transformer’s
terminals.
4.
Touch the test leads to the transformer
LINE (primary) terminals. The ohmmeter
should indicate 40 to 45
Ω
.
5.
Touch the test leads to the transformer
LOAD (secondary) terminals. The ohm-
meter should indicate less than 1
Ω
.
Primary
120 VAC
40 - 45
Ω
Secondary
20.3 VAC
Less than 1
Ω
Electrical Shock Hazard
Disconnect the electrical supply from the
unit before servicing.
Failure to do so could result in death or
electrical shock.
WARNING
LINE (PRIMARY)
LOAD (SECONDARY)
CONTROL POWER & LAMP TRANSFORMERS