3-5
OVEN TEMPERATURE SENSOR
TEST PROCEDURE
Refer to page 2-15 for the procedure for ser-
vicing the oven temperature sensor.
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R x 10 scale.
3.
Disconnect the oven temperature sensor
connector from the wiring harness.
4.
Touch the ohmmeter test leads to the
oven temperature sensor connector pins.
Depending on the oven temperature, you
should obtain the corresponding resis-
tance reading, as shown in the following
chart:
Resistance Test (At The Electronic
Range Control)
NOTE: To test the oven temperature sensor at
the electronic range control, perform the fol-
lowing steps (see page 2-4 for removing the
top access panel).
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R x 100 scale.
3.
Disconnect the P7-4 (violet) and the P7-5
(violet) wire connectors from the elec-
tronic range control.
4.
Touch the test leads to the P7-4 (violet)
and the P7-5 (violet) wire connectors. The
ohmmeter should indicate approximately
1080
Ω
at 70˚F (21˚C).
Electrical Shock Hazard
Disconnect the electrical supply from the
unit before servicing.
Failure to do so could result in death or
electrical shock.
WARNING
Temperature (˚F)
Resistance (ohms)
32
1000
75
1100
250
1450
350
1650
450
1860
550
2050
650
2230
900
2700
Connector
Oven
Temperature
Sensor