Varisol Installation Manual
09
08
Attaching the Connection Kit
Step Eight
(return connection)
1. Assemble and connect end fittings (Male
connection A, T connection G &
Air bleeding valvue E)
2. Open lid on left hand end tube fitting
3. Place rubber seal (D) on male end of collector area
(blocking upper chamber)
4. Secure in position with clip (F)
5. Ensure clip (F) legs protrude out of
bottom of enclosure
6. Complete and attach technical label (I)
7. Close lid and secure with screw
E
G
A
D
F
I
Qty. Tubes
A
B
C
D
E
F
G
H
I
Step Nine
(flow connection)
1. Assemble and connect end fittings (Female
connection B, T connection G & Temperature
sensor pocket H)
2. Remove securing pin from female
end of collector
3. Place rubber seal (C) in female end of
collector area (blocking lower chamber)
4. Secure in position by relocating securing pin
B
G
H
C
A
B
C
D
E
F
G
H
I