background image

Varisol Installation Manual

21

20

Warranty Statement

Kingspan Renewables Ltd

Warranty Statement for Solar

Subject to the following provisions, Kingspan Renewables Ltd warrants that the Goods will be free from 

defects in material and workmanship for a period of 5 years in relation to KINGSPAN SOLAR

PRODUCTS. The warranty is given by Kingspan Renewables Ltd subject to the following conditions:
A.      Kingspan Renewables Ltd shall be under no liability in respect of any defect in the Goods arising from 

any information drawing design or specification supplied by the Buyer

B.   Kingspan Renewables Ltd shall be under no liability in respect of any defect arising from fair wear 

and tear, wilful or accidental damage, negligence, abnormal working conditions, failure to follow the  

Kingspan Renewables Ltd design and installation instructions, misuse or alteration or repair of the   

Goods without approval

C.    The above warranty does not extend to parts materials equipment not manufactured by Kingspan 

Renewables Ltd in respect of which the Buyer shall only be entitled to the benefit of any such warranty or 

guarantee as is given by the manufacturer to the Company.

D.    The defect has been reported by the Buyer to Kingspan Renewables Ltd within the warranty period

E.   The installation of the Goods having been carried out by fully trained and competent person(s)

F.     The Goods having been subjected to neither “prolonged stagnation conditions” nor exhibiting signs of 

“extreme temperature exposure”

1.     The Buyer shall not make any statement or representation or give any warranty to any third party in 

respect of any Goods other than in the terms made or given by Kingspan Renewables Ltd to the Buyer nor 

shall the Buyer have any authority to commit Kingspan Renewables Ltd to provide any service in relation 

to the Goods.

2.    The Company’s liability to the Buyer for death or injury resulting from its own or that of its employees’ 

agents’ or subcontractors’ negligence and damage suffered by the Buyer as a result of any breach of the 

obligations implied by Section 12 of The Sale of Goods Act 1979 shall not be limited.

3.    If Kingspan Renewables fails to deliver the Goods for any reason other than any cause beyond the 

Company’s reasonable control or the Buyer’s fault then Kingspan Renewables Ltd shall only be liable to 

the Buyer for and the Company’s liability shall be limited to the excess (if any) of the cost to the Buyer (in 

the cheapest available market) of similar goods to replace those not delivered over the Price of the Goods.

4.    The Buyer shall examine all delivered Goods forthwith. Any claim based on any defect in the quality 

or condition of the Goods or their failure to correspond with specification shall be notified to Kingspan 

Renewable Ltd within 7 days from the delivery date or where the defect was not apparent on reasonable 

inspection within a reasonable time after discovery of the failure. If delivery is not refused and the Buyer 

does not notify Kingspan Renewable Ltd the Buyer shall not be entitled to reject the Goods.

5.    Kingspan Renewables Ltd shall be entitled to examine any Goods, which are the subject of any claim by 

the Buyer, and to remove such Goods or any part thereof for testing. No tests carried out by the Buyer 

will be recognised by Kingspan Renewables Ltd unless carried out strictly in accordance with a method 

previously agreed by Kingspan Renewables Ltd as being suitable for the purpose.

6.     Any valid claim in respect of the Goods which is based on any defect in the quality or condition of the 

Goods or their failure to meet specification is notified to Kingspan Renewables Ltd in accordance with 

these Conditions Kingspan Renewables Ltd shall be entitled to repair or replace the Goods (or the 

part in question) free of charge or at the Company’s sole discretion refund to the Buyer the Price (or a 

proportionate part of the Price) but Kingspan Renewables Ltd shall have no further liability to the Buyer.

7.     Kingspan Renewables Ltd shall not be liable to the Buyer by reason of any representation (unless 

fraudulent) or any implied warranty condition or other term or any duty at common law (including but 

without limitation the negligence of Kingspan Renewables Ltd its employees agents or otherwise) or under 

the express terms of the Contract for any loss of production loss of profits or anticipated profits loss of 

contracts operation time or anticipated savings loss of business or of expected further business loss of 

or corruption to data damage to the Buyer’s reputation or goodwill damages costs or expenses payable 

by the Buyer to any third party or any other indirect special or consequential loss or damage or claim 

(whether caused by the negligence of Kingspan Renewables Ltd its employees agents or otherwise) which 

arise out of or in connection with the supply of the Goods or their use or resale by the Buyer.

8.     Without prejudice to the provisions of clauses 3, 4, 5, 6 and 7 the entire liability of the Buyer under or in 

connection with the Contract shall not exceed the Price of the Goods.

9.     Kingspan Renewables Ltd shall not be liable to the Buyer or be deemed to be in breach of the contract by 

reason of any delay in performing or any failure to perform any of the Company’s obligations in relation to 

the Goods if the delay or failure was due to any cause beyond the Company’s reasonable control. Without 

limiting the foregoing, due to causes beyond the Company’s reasonable control.

10.  For comprehensive details regarding “Warranties and Liability” please refer to the “CONDITIONS OF 

SALES” section 7.

Содержание Varisol

Страница 1: ...Renewables Installation Manual...

Страница 2: ...alling Tubes 7 Attaching the connection kit 9 Pump station 12 Safety vessel connections 13 Wiring the control panel 14 Commissioning the system 16 Decommissioning the system 17 Recycling Information 1...

Страница 3: ...idance Tube boxes should be transported horizontally Heavy goods should not be loaded on top of the kit boxes Care should be taken when opening boxes to prevent scratches or sudden shocks to the glass...

Страница 4: ...ts Flexi Connections Cooling Vessel DF100 only Expansion Vessel Tyfocor LS Connection Kit Tubes Insulated Hose Mounting Set Solar Roof Flashing 22mm 3 Port Diverter Valve Note 15 28mm also available 2...

Страница 5: ...21 5 300 22 35 6 360 22 53 7 420 22 80 8 480 22 110 9 540 22 153 Collector Area m2 Varisol Collector Expansion Vessel Sizing System Volume Ltr Expansion Vessel Size Ltr Cooling Vessel Size Ltr Static...

Страница 6: ...or tubes and be difficult to flush out Airlocks in the pipes will stop circulation through the system When the collector is orientated correctly i e with the manifold slightly higher than the base of...

Страница 7: ...d collector the available rafter spacing should be considered when sizing the collector to ensure that an appropriate side rail spacing can be achieved Roof Kit Sizing 05 Collector Number of Kit Type...

Страница 8: ...ackets C to roof using M8x50 coachscrews E 3 Secure side rails A to lower brackets using M10x65 bolt assy Step Two 1 From upper end of each side rail slide 2 M8x16 bolt into position 2 Secure side rai...

Страница 9: ...upper and lower support rail to 90 bracket as shown below 07 Installing the first tube Step Four 1 Align first tube with end of support rail and push home by clicking into rail push on upper push poi...

Страница 10: ...otection is removed first Step Six 1 Rotate second tube parallel with first tube 2 Locate upper plastic enclosure and lower tube support clip in rail 3 Push home the upper and lower fittings into the...

Страница 11: ...F 5 Ensure clip F legs protrude out of bottom of enclosure 6 Complete and attach technical label I 7 Close lid and secure with screw E G A D F I Qty Tubes A B C D E F G H I Step Nine flow connection 1...

Страница 12: ...EX ALU PEX or GALVANISED TUBING OR FITTINGS SHOULD NOT BE USED UNDER ANY CIRCUMSTANCES Flexible Pipe Connections Flexible pipe connections are recommended to connect the manifold through the building...

Страница 13: ...pression fittings provided for direct copper connection C0784 Insulated Hose Stub Fitting When flexible stainless steel pipe is being used to connect to the pump station the insulated hose stub fittin...

Страница 14: ...upplied includes an appropriate corrugated hose and threaded connection to join the vessel to the pump station Temperature Reducing Vessel TRV Also known as a cooling vessel or stratification vessel t...

Страница 15: ...in core copper cable with a 0 75mm cross section The sensors supplied are 1 5 metres in length Sensor cables can be extended with twin core copper cable of 0 75mm diameter up to 50 metres and 1 50mm d...

Страница 16: ...i e for an east west panel array or a stagnation configuration requiring a second pump Caution Avoiding damage and malfunctions When connecting an external relay or contactor or when connecting a pump...

Страница 17: ...e above the flow meter to ensure all air and liquid passes through the fill centre to filter any air and contaminants 4 Run the fill centre pump to circulate the Tyfocor LS for approximately 20 minute...

Страница 18: ...ceeding 170 C and pressures greater than 6 bar a solar installation should only be decommissioned by a trained individual The system should be decommissioned in low light ideally in the morning when t...

Страница 19: ...ith water Propylene glycol is not harmful to aquatic organisms and is readily biodegradable however the disposal of the solution should be done in a responsible manner taking into consideration local...

Страница 20: ...ifreeze properties the system should be refilled with fresh Tyfocor LS It is recommended that the solar system is serviced annually by a qualified engineer and immediately if the system shows evidence...

Страница 21: ...111 177 287 177 287 266 430 137 137 137 137 206 206 8 8 to 20 20 Tube Collector Height Above Ground m 30 Tube Collector 10 Tube Collector 20 Tube Collector 30 Tube Collector Weight Per Foot kg 45 Wind...

Страница 22: ...pond with specification shall be notified to Kingspan Renewable Ltd within 7 days from the delivery date or where the defect was not apparent on reasonable inspection within a reasonable time after di...

Страница 23: ...21...

Страница 24: ...opment and improvement we reserve the right to alter and amend the specification as shown in this literature Kingspan Renewables Limited 180 Gilford Road Portadown Co Armagh Northern Ireland BT63 5LF...

Отзывы: