12
is applied, the insulation on the wire may be damaged. If too little pressure is applied, the
quality of the imprint will be unsatisfactory.
Dwell is the length of time the hot type is in contact with the foil and the marking surface.
The timer controls dwell.
The correct balance of all three elements is required for a quality imprint. Experiment with
particular insulation and foils will determine exact settings. If the settings are not known,
use the following as a starting point.
Temperature: 250
F
Air Pressure: 20 psi
Dwell: ½ second
TEMPERATURE SETTING
Temperature controller is set for the unit of measure normally used in your location, F
or
C
. Kingsley recommends not changing the unit of measure. If you need to make this
change, please contact Kingsley before attempting to do so.
Use the following procedure to change the temperature set point:
NOTE: A single press
o
f
key on the temperature control displays the
current set point.
1. Press and hold the
key.
2. Press to increase set point.
3. Press and hold the
key.
4. Press to decrease set point.
5. When the keys are release, the controller displays the actual temperature
of the typewheel mandrel.
PRESSURE SETTING