Enter the alarm threshold value with the rotative button and press
OK
to validate.
➢
Validate the threshold with the right function key
.
➢
Validate the modifications with the function key
.
➢
Press
Esc
to quit the screen.
4.3.2. Set measurement units
It is also possible to select the measurement unit for each measured parameter :
•
Temperature :
°C, °F
•
Pressure :
Pa, inWg, hPa, mbar, mmHg, mmH
2
O, PSI
•
CO / CO
2
/ NO / NO
2
/ NOx / SO
2
:
ppm, mg/m
3
, mg/kWh, g/kWh, g/GJ, g/m
3
, %
•
CH
4
:
ppm, %vol, %LIE
“Settings”
menu is displayed.
➢
Go to
“Measurement”
with the rotative button then press
OK
.
➢
Go tor
“Units”
with the rotative button then press
OK
➢
Go to the parameter to modify with the rotative button then press
OK
.
The list of the available units according the parameter appears.
➢
Go to the requested unit with the rotative button then press
OK
.
➢
Press
Esc
to quit the screen.
4.3.3. Set the CO protection threshold
The CO protection allows to protect the instrument against high concentrations of CO. Above the threshold, the instrument will stop the
measurement of CO but the others measurements will stay possible. To set this threshold :
“Settings”
menu is displayed.
➢
Go to
“Measurement”
with the rotative button then press
OK
.
➢
Go to
“CO protection”
with the rotative button then press
OK.
➢
Press the function key
to modify the threshold.
➢
Enter the requested threshold then press the function key
to validate the threshold.
➢
Press
Esc
to quit the screen.
4.4. Set the references
Settings>References
screen allows to set the features of the measurement environment : O
2
reference, altitude and atmospheric pressure. These
data are used to calculate the efficiency.
These settings must be performed by a qualified technician.
“Settings”
screen is displayed.
➢
Go to
“Reference”
with the rotative button then press
OK
.
➢
Select the parameter to modify with the rotative button then press
OK
.
The keyboard appears.
➢
Enter the parameter value with the rotative button then press
OK
to validate.
➢
Validate the parameter value with the function key
.
4.5. Set the duration of autozero and purge time
The autozero allows the analyser to exhaust ambient fresh air and as a result to put the sensors at 0 ppm.
“Settings”
screen is displayed.
➢
Go to
“Autozero”
line with the rotative button then press
OK
.
➢
Press
OK
.
The list of available duration appears.
➢
Go to the required duration then press
OK
.
➢
Press
Esc
to quit the screen.
4.6. Set the operators
It is possible to enter in analyser names of operators who will use the instrument. The operator who performs an analysis appears on the ticket (only
for the long size).
4.6.1. Add an operator
“Settings”
screen is displayed
.
➢
Go to
“Operator »
with the rotative button then press
OK
.
➢
Press the function key
.
The keyboard appears.
➢
Enter the name with the rotative button : press
OK
to validate.
➢
Press the function key
to validate the operator name
and to add it in the list.
18
Set the different parameters of the analyser
netzerotools.com
netzerotools.com
Содержание Kigaz 300 CLA
Страница 2: ...netzerotools com netzerotools com...
Страница 6: ...netzerotools com netzerotools com...
Страница 39: ...Calculations of the different parameters 39 netzerotools com netzerotools com...
Страница 51: ...netzerotools com netzerotools com...
Страница 52: ...netzerotools com netzerotools com...