FingerVein Online
Installation and Programming Manual
Page
62 of 69
• Relays:
- Connect as required (J3 connector). Normally-open contacts.
• Button:
- Connect between pin 5 (DIN_1) and pin 2 (GND) of the J2 connector.
• Display:
- Connect directly to J17.
- Set the contrast using potentiometer, P2.
• Ethernet Cable:
- Connect directly to J7.
A.1.2. Terminal configuration
• Network parameter configuration:
The KSearch demo application can be used to configure the Ethernet parameters
of the terminal, which mean that all the terminals available in an operating
network can be located and configured.
• Operating parameter configuration:
To configure the operating parameters for the terminal, communicate with the
terminal via any of its protocols and configure the following parameters:
Table 13: Fing Mifare Pinout connections
Signal
KRD13Mv2
FingerVein
5Vdc
Pin 1 of terminal J2
Pin 4 of terminal J10
GND
Pin 2 of terminal J2
Pin 3 of terminal J10
Rx - Tx
Pin 3 of terminal J2
Pin 2 of terminal J10
Tx - Rx
Pin 4 of terminal J2
Pin 1 of terminal J10