FingerVein Online
Installation and Programming Manual
Page
20 of 69
$09
Configuration byte of the automatic beeper ena-
bling after a correct Clock&Data reading.
Refer to
$0A
Configuration byte of the automatic beeper ena-
bling after an incorrect Clock&Data reading.
Refer to
$0B
Configuration of the multiread filtering.
Refer to
$0C
Time-out in tenths of a second of the multiread fil-
tering, to detect that a card has left the reading
field.
Refer to
$0D
Configures the communications channel through
which the event frames are sent.
(In DB module)
Refer to
$0E
Time-out, before starting the biometric sensor.
Refer to
$0F
to
$13
Reserved
$14
Time-out of the communication with the display
Refer to
$15
to
$19
Reserved
$1A
Determines the protocol and Baud Rate assigned
to the UART0-UI. Do not change
.
Refer to
$1B
Determines the protocol and Baud Rate assigned
to the UART1-UI. Do not change
.
Refer to
$1C
Determines the protocol and Baud Rate assigned
to the UART2-UI. Refer to
Refer to
$1D
Do not change
$1E
Reserved for future uses.
$1F
Time, in tenths of a second, to indicate correct
reading with the green LED.
Refer to