FingerVein Online
Installation and Programming Manual
Page
22 of 69
8.1.2. Event configuration
FingerVein Online electronics has the capacity to start communications to the Host when
any event occurs in the machine (e.g. a key is pressed). The following parameters can be
configured:
Table 3: Reader configuration codes
Type of Reader
Parameter and values
Details
Communication with the
Host, Bio-OCX protocol
CFG-UI_ HostSerialPort
$90: 9600 baud
$91: 19200 baud
$92: 38400 baud
Only UART0-UI
FingerVein Sensor
CFG-UI_ReaderSerial-
Port
$BB: 57600 baud
Only UART1-UI
RS232 Online
a
Reader
a. Use these values for totally Online serial readers (e.g. SC6000 or KRD13M in Online mode)
CFG-UI_AuxSerial-Port
$88: 9600 baud
$89: 19200 baud
$8A: 38400 baud
$8B: 57600 baud
Mode without format,
totally transparent.
Only UART2-UI
RS-232 card reader
(Automatic Mode)
CFG-UI_AuxSerial-Port
$40: 9600 baud
$41: 19200 baud
Also enable
CFG_Reader_Enable
b
b. Use these values for serial readers with Automatic Reading Mode enabled (e.g. KRD13M or
SC42). Refer to
UART disabled
CFG-UI_AuxSerial-Port
$F0
Only UART2-UI
Table 4: Event configuration
No.
Description
Def.
$01
CFG-DB_
ECHO
Defines the events reported to the Host (DB mod-
ule)
$50
$04
CFG-UI_
SCITimeout
Time-out of the reception of the UART from the
RS232 reader(UART2-UI)
$FF
$0D
CFG-UI
_EventCH
Communications channel through which the elec-
tronics will generate the event frame. Refer
to
$FF