FingerVein Online
Installation and Programming Manual
Page
28 of 69
For all the parameters described in the table, the configuration value corresponds to
the time in multiples of 10 ms that they are to remain enabled:
- With a correct reading for which
CFG-UI_Reader_BuzOK
is enabled, the internal
buzzer (
CFG-UI_TempBuzz_OK
) will be triggered.
- With an incorrect reading for which
CFG-UI_Reader_ BuzError
is enabled, the
internal buzzer (
CFG-UI_Temp-Buzz_Fail
) will be triggered.
Permitted values:
- 0xFF: Permanently enabled.
- 0x01 .. 0xFE: Timing in
multiples of 10 milliseconds
.
- 0x00: Timing disabled.
Default value:
depending on parameter (see table)
8.1.6. Others
Byte
$14
:
Display time-out
. Time-out (in cycles) after writing on the Display.
Permitted values:
- 0xFF: default value. This is a very conservative Time-out.
- 0x0F: recommended value if the display is not connected to the FingerVein Online
electronics (the default value, 0xFF, slows down the operation of the electronics
in this case).
Default value:
- 0xFF: maximum value of display Time-out.
Table 9: Internal buzzer timing
No.
Description
Def.
$06
CFG-UI_TempBuzz1_
OK
Internal buzzer, OK key pressed
$06
$07
CFG-UI_TempBuzz1_
Fail
Internal buzzer, error (not used)
$78
Table 10: Other configuration parameters
No.
Description
Def.
$14
CFG-UI_DisplayTMO
Maximum time-out of the Display
$FF