BioMax2 / KBio2-Online
Installation and Programming Manual
Page
39 of 91
Permitted values:
- Bit 0 (LSB): Internal buzzer enabled for UART0.
- Bit 1: Internal buzzer enabled for UART1.
- Bit 2: Internal buzzer enabled for TTL_0.
- Bit 3: Internal buzzer enabled for TTL_1.
- Bit 4: External green LED and buzzer enabled for UART0.
- Bit 5: External green LED and buzzer enabled for UART1.
- Bit 6: External green LED and buzzer enabled for TTL_0.
- Bit 7: External green LED and buzzer enabled for TTL_1.
Default value:
- 0x0C: Internal buzzer enabled for TTL_0 and TTL_1.
Buzzer on Fail
. Buzzer configuration for incorrect readings. We can
enable the buzzer assembled on the
BioMax2
/ KBio2-Online
(internal), or a set of
external buzzer and red LED, so that they are enabled when an incorrect reading has
occurred.
- Bit 0 (LSB): Internal buzzer enabled for UART0.
- Bit 1: Internal buzzer enabled for UART1.
- Bit 2: Internal buzzer enabled for TTL_0.
- Bit 3: Internal buzzer enabled for TTL_1.
- Bit 4: External red LED and buzzer enabled for UART0.
- Bit 5: External red LED and buzzer enabled for UART1.
- Bit 6: External red LED and buzzer enabled for TTL_0.
- Bit 7: External red LED and buzzer enabled for TTL_1.
Default value:
- 0x0C: Internal buzzer enabled for TTL_0 and TTL_1.
:
Multiread
. This enables multiread filtering of the Clock&Data and
RS232 inputs.
Multiread filtering is useful for when we have a reader configured in
multiread mode connected to the card (every X time the reader checks the presence
of the card and if it is present it generates an event with the card's identification
information). This mode allows for filtering all the events that correspond to a same
card and only generates events when it varies with the reading data.