10. Biometric identification
The
BiomaxPlus
communications protocol provides a set of high-level instructions to
simply handle the biometric sensor.
The following instructions will be used as arguments in the
command
indicated in
These GCR instructions are initially intended to work with a main FIM and the
BiomaxPlus-DB
auxiliary board. However, they also work, though partially, for one or
two FIM modules, even when no
BiomaxPlus-DB
is present. In order to achieve that,
(associated to commands
‘71x’
(associated to commands
‘72x’
) must be properly configured (that is, with a value of
$04
or
$05
).
If the available FIM module does not support Auto-On detection, the following
instructions may still be used, but
must be set to
$80
or similar.
10.1. Basic instructions
10.1.1. Retrieve sensor version
Function: It allows for the type of biometric sensor installed in the terminal and its
firmware version to be retrieved.
Instruction
‘714’ / ‘724’
Description
‘714’
Instruction code. Intermediate digit addresses Main
FIM (‘1’) or auxiliary (‘2’).
No argument
Response
‘814tttaaaabbbb’ / ‘824tttaaaabbbb’
Description
‘814’
Response code. Intermediate digit addresses Main
FIM (‘1’) or auxiliary (‘2’).
‘ttt’
Sensor type. Possible values:
FIM - FIM-type biometric sensor.
‘aaaa’
Information on sensor part number.
- Usual value: ‘5360’
‘bbbb’
Information on FW version.
- Example: ‘0114’ (versión 1.14)