BioMax2 / KBio2-Online
Installation and Programming Manual
Page
69 of 91
10.2. Capture of biometric information
10.2.1. Capture of biometric information
Función: It captures templates from user’s fingerprint scan operation.
Instruction
‘713’ / ‘723’
Description
‘713’
Instruction code. Intermediate digit addresses Main
FIM (‘1’) or auxiliary (‘2’).
nn
Optional argument specifies the number of templa-
tes to scan (‘01’ or ‘02’). If no argument, one tem-
plate is scanned when in FIM30 emulation mode,
and two scans when in FIM20 emulation mode.
Response
‘813rr’ - ExtraData: ‘hhh...hhh’ /
‘823rr’ - ExtraData: ‘hhh...hhh’
Description
‘813’
Response code. Intermediate digit addresses Main
FIM (‘1’) or auxiliary (‘2’).
‘rr’
Operation result. Possible values:
11 - Operation completed correctly.
‘hhh...hhh’
The captured template is sent on the Extra-Data
field of the response frame. Template length
depends on emulation mode (FIM20 vs. FIM30).