Chapter 3: Configuration and commissioning
44
KFP-A Series Installation Manual
Control panels in the same network can have different day/night mode sensitivity
settings.
If the command filter is configured accordingly, a control panel can operate a
local day/night mode setting independently from other control panels in the same
network. A local day/night mode setting is indicated on the local control panel
LCD by the corresponding icon. See “Icons displayed on the LCD” on page 11.
If the control panel is a repeater, remember that the day/night mode displayed
corresponds to those control panels configured to accept the global sensitivity
mode command. Some control panels in the network may be operating with
locally-defined sensitivity settings.
The day/night mode setting for all control panels in a fire network is included in
the Firenet status report.
For more information on the global controls, see “Global controls” on page 58.
The Communications menu
Use the Communications menu to set up email accounts for event notifications
and to safely remove a USB device connected to the control panel.
Managing email accounts
Select Email accounts to manage the email accounts for remote monitoring and
to configure the notifications sent to each email address.
To configure email accounts:
1. Select Communications from the Main menu.
2. Select Email accounts, and then select the account to be edited (the default
names are Account 1, Account 2, etc.).
3. Check the notifications to include in the email: alarm events, fault events,
condition events, log events, or reports.
If no notifications are checked, the notification service is not activated.
4. Enter the email address associated with the email account.
5. Press F4 (Enter), and then press F1 (Back).
6. Press F1 (Save), F3 (Apply), F4 (Discard), or F2 (Exit).
Remember to apply saved settings from the Main menu.
Note:
This feature requires TCP/IP and email server details to be configured.
Removing a USB device
Select Remove USB device to safely remove a USB device connected to the
control panel (for example, a flash drive).
Caution:
Failure to remove a USB flash drive as described may result in loss of
data and/or damage to your flash drive.
Содержание KFP-AE1(-S)
Страница 1: ...KFP A Series Installation Manual P N 00 3252 501 0003 04 ISS 04MAY15...
Страница 6: ...iv KFP A Series Installation Manual...
Страница 20: ...Chapter 1 Introduction 14 KFP A Series Installation Manual...
Страница 113: ...Chapter 3 Configuration and commissioning KFP A Series Installation Manual 107...
Страница 114: ......
Страница 126: ...Chapter 5 Technical specifications 120 KFP A Series Installation Manual Figure 27 Large cabinet dimensions and views...
Страница 127: ...Chapter 5 Technical specifications KFP A Series Installation Manual 121 Figure 28 Small cabinet dimensions and views...
Страница 128: ...Chapter 5 Technical specifications 122 KFP A Series Installation Manual...
Страница 142: ...Appendix C Menu maps 136 KFP A Series Installation Manual...
Страница 148: ......