![Kilsen KFP-AE1(-S) Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/kilsen/kfp-ae1-s/kfp-ae1-s_installation-manual_1967142017.webp)
Chapter 1: Introduction
KFP-A Series Installation Manual
11
Icons displayed on the LCD
Icons displayed on the LCD are shown below.
Table 5: LCD icons and descriptions
Icon
Description
Day mode (network)
This icon indicates that the primary sensitivity mode
setting for control panels in the fire network is day
mode.
Day mode (control panel)
This icon indicates that the sensitivity mode for the local
control panel is day mode. Other control panels in the
fire network may have a different sensitivity mode
setting.
Night mode (network)
This icon indicates that the primary sensitivity mode
setting for control panels in the fire network is night
mode.
Night mode (control panel)
This icon indicates that the sensitivity mode for the local
control panel is night mode. Other control panels in the
fire network may have a different sensitivity mode
setting.
Fire alarms
The number beside this icon indicates the number of
zones with an active fire alarm. Alarm information for
the first and last zones to report an alarm is displayed in
the LCD message area
.
Faults
The number beside this icon indicates the number of
active faults. Additional information is available by
pressing F1 (Show Events).
Conditions
The number beside this icon indicates the number of
active system conditions. Additional information is
available by pressing F1 (Show Events).
Stand-alone
This icon indicates that the control panel is not
connected to the fire network.
Networked
This icon indicates that the control panel is connected
to the fire network.
Repeater
This icon indicates that the control panel is configured
to operate as a repeater and is connected to the fire
network.
Detector alarm [1]
This icon indicates a detector alarm.
Manual call point alarm [1]
This icon indicates a manual call point alarm.
Manual call point alarm
(sprinkler) [1]
This icon indicates a manual call point alarm (sprinkler).
Manual call point alarm
(“hausalarm”) [1]
This icon indicates a manual call point alarm
(“hausalarm”). This is a local alarm with no fire routing
activation.
[1] These icons appear in the message display area with the notification details.
Содержание KFP-AE1(-S)
Страница 1: ...KFP A Series Installation Manual P N 00 3252 501 0003 04 ISS 04MAY15...
Страница 6: ...iv KFP A Series Installation Manual...
Страница 20: ...Chapter 1 Introduction 14 KFP A Series Installation Manual...
Страница 113: ...Chapter 3 Configuration and commissioning KFP A Series Installation Manual 107...
Страница 114: ......
Страница 126: ...Chapter 5 Technical specifications 120 KFP A Series Installation Manual Figure 27 Large cabinet dimensions and views...
Страница 127: ...Chapter 5 Technical specifications KFP A Series Installation Manual 121 Figure 28 Small cabinet dimensions and views...
Страница 128: ...Chapter 5 Technical specifications 122 KFP A Series Installation Manual...
Страница 142: ...Appendix C Menu maps 136 KFP A Series Installation Manual...
Страница 148: ......